AAVA ATEX

ATEX HIGH PRESSURE WITH BACKWARD IMPELLER

MANUFACTURING FEATURES:

• Fan made of Fe360 sheet. The fan paint finish is based on a Qualicoat polyester powder coating stoved at 200ºC, with an average film thickness of 70 microns. Average heat resistence of coating is 180ºC with peaks of 200ºC.
• High efficiency simple inlet backward impeller with self-cleaning system made of Fe360 sheet statically and dynamically balanced. Impellers are painted with polyester primer that resists temperatures up to 300ºC.
• ATEX standard asynchronous motor. ATEX certified according to the zone. Squirrel-cage motor with class F insulation. Manufactured with standard voltages: 230/400V 60Hz in three phase motors up to 4kW and 400/690V 60Hz for higher powers.

• Available positions (to be indicated in case of order): LG270, LG0, LG45, LG90, LG135, LG180, LG225, LG315, RD0, RD45, RD90, RD135, RD180, RD225, RD270, RD315.
• The indicated codes correspond to the model in position LG270

APPLICATIONS:

Designed for inline installation, they are suitable for:
• Industrial applications, extraction or injection of air.
• Cooling of machines and parts.
• Clean air transport.
• Exhaust after filters, separators and cyclones.
• Pneumatic transport.
• Working temperature: ambient from -20ºC to 40ºC, transported air according to the ATEX clasification.

UNDER REQUEST

· Fans for 50Hz and special voltages.
· Inox 304 (normal or electropolished finish)
· Inox 316 (normal or electropolished finish)
· Split casing (for big sizes)
· Drain plug.
· Frontal foot

Code Name
- AAVA 711/P T2 3kW ATEX
- AAVA 712/P T2 4kW ATEX
- AAVA 801/P T2 4kW ATEX
- AAVA 901/P T2 11kW ATEX
- AAVA 1002/P T2 22kW ATEX
- AAVA 500/P T2 1,1kW ATEX
- AAVA 560/P T2 1,5kW ATEX
- AAVA 631/P T2 1,5kW ATEX
- AAVA 632/P T2 2,2kW ATEX
- AAVA 802/P T2 5,5kW ATEX
- AAVA 803/P T2 7,5kW ATEX
- AAVA 350/P T2 0,37kW ATEX
- AAVA 400/P T2 0,55kW ATEX
- AAVA 450/P T2 0,75kW ATEX
- AAVA 1001/P T2 18,5kW ATEX