fan image
Model
NIMUS 901 T4 45kW (std)
Code
NS90142256

NIMUS 901 T4 45kW (std)

CENTRIFUGAL FAN, FOR CLEAN OR SLIGHTLY DUSTY AIR

MANUFACTURING FEATURES

• Medium pressure centrifugal fan with direct coupling.
• Reinforced housing made of carbon laminated steel, protected against corrosion by powder coating polyester resin RAL 5010. Finish C3.
• Casing fully latched and adjustable.
• Self-cleaning turbine and reinforced impeller with high-performance backward (reaction) blades made of carbon laminated steel dynamically balanced to minimize noise and vibrations. Black painted RAL 9005
• Squirrel cage standardized asynchronous IEC motor with IP-55 protection and class F electrical insulation. Standard voltages 230/400-460V 60Hz for three-phase motors up to 4kW and 400-460/690V 60Hz for higher powers. IE4 motors for 75kW power or higher.
• Motor with feet (B3) supported on motor support foot.
• Models of size 500 and above are supplied with a front support foot, for the other models the front support foot is optional.
• Maximum working temperature in continuous: air transported: 130ºC, Environment: 60ºC.

• Available positions (to be indicated in case of order): LG270, LG0, LG45, LG90, LG135, LG180, LG225, LG315, RD0, RD45, RD90, RD135, RD180, RD225, RD270, RD315.
• The indicated codes correspond to the model in position LG270

APPLICATIONS

Suitable for moving clean or dusty air. Designed to be installed in conduit for suction or impulsion.

  •      Paint booths
  •      Collection of dust
  •      Food industry dryers
  •      Food processing
  •      Incineration
  •      Odor control in industry
  •      Indoor / outdoor pollution control
  •      Big buildings
  •      Malls
  •      Factories / Industrial buildings
  •      Warehouses
  •      Extraction of smoke
  •      Boilers and ovens
  •      Manufacture and treatment of chemical products.
  •      Tunnels, underground stations.

ON DEMAND

· Fans for special voltages.
· 2 speed motor.
· C4 or C5 coating painting
· Hot dip galvanized
· Inox 304 (normal or electropolished finish)
· Inox 316 (normal or electropolished finish)
· Cooling wheel
· Anticaloric paint
· Fully welded housing (waterproof)
· Inspection door to facilitate maintenance and cleaning
· Drain plug.
· Airtight axle
· Non-sparking air passage and standard motor
· Other brands of motors.

 

Fan

Max flow
65960 m³/h
Weight
878 Kg

Motor

Power
45 kW
RPM Motor
1770
I max. 400 V
80,7
I max. 690 V
46,8
Size
225M
Weight
363 Kg
Efficiency
94.4 %
FP
0.86
NIMUS 901 T4 45kW (std)
Loading...
Design point
Loading...
Service point
Loading...
Alternative point

NIMUS 901 T4 45kW (std)

Dimensions scheme
A1 A2 B1 B2 C1 C2 C3 C4 C5 D D1 D2 E F (±) G (±) H HC I J K L M N N1 N2 O P Q R R1 R2 S T U V Y Z
1059 724.6 605.9 877.2 648.2 1177.3 953.6 800.9 87.3 987 11.5 20 1404.1 1419.4 576 68.5 1090 693.6 747.8 727.6 580 223.5 647 567 617 260 260 682.5 980 900 950 835 913 188.4 149.4 M12 16x22,5º

NIMUS 901 T4 45kW (std)

Electrical scheme

NIMUS 901 T4 45kW

Model
BA-400 90
Code
960002061
Information
ANTI-VIBRATING FLANGE 400º/2H

MANUFACTURING FEATURES

• Flexible polyurethane coupling flange with fiberglass fabric to avoid possible vibrations to the installation.
• 160 mm width and supplied with 2 fixing clamps.
• Certified according to the European standard EN 12101-3 400ºC/2h. Fire classification: M0.

Model
JE 45
Code
A-300719201
Information
ANTI-VIBRATION JOINT

MANUFACTURING FEATURES

• Flexible joint to clinch the fan to the duct.
• Avoids transmission of vibrations for circular and rectangular connection.
• Dimensions: two metallic flanges of 45mm each one and a flexible flange of 60mm.
• The reel is 30,5m lenght.
• Maximum pressure: 20 mmca.
• Fire resistance M0 from -50ºC to +200ºC in continuous and 400ºC/2h.

Model
EIS 900x567-900
Code
EIS-9056790
Information
OUTLET FLANGE FOR STORM MODELS

MANUFACTURING FEATURES

• Connection flange for rectangular outlet of STORM centrifugal fans making the connection to circular duct easier.
• Manufactured in galvanized steel.

UNDER REQUEST

• Versions in stainless 304 and stainless 316.

Model
BADS 900
Code
BADS-9090
Information
CIRCULAR-CIRCULAR ANTI-VIBRATION FLANGE FOR STORM

MANUFACTURING FEATURES

• Circular-circular coupling flange through anti-vibration canvas.
• Supplied with two O-shaped plates made of galvanized sheet metal and necessary screws.

Model
RA 90
Code
A-243901901
Information
INLET PROTECTION GUARD FOR CENTRIFUGAL FANS

MANUFACTURING FRATURES

• Inlet protection guard to avoid the entry of objects and contact with the impeller.
• Made of galvanised steel models 7,9, 10, 12 and 15. And the rest of models with polyester powder finishing coat.

Model
RIS 900x567
Code
RIS-90567E2
Information
OUTLET PROTECTION GUARD FOR STORM FANS

MANUFACTURING FRATURES

• Protective grid for outlet installation in STORM medium pressure fans.
• Made of rolling steel sheet, protected against corrosion by powder coating of polyester resin.

*The Storm fan can be a NIMUS, NIMAX, PRESTUR, PREXTUR or IGNÉO

Model
BIDS 567x900-200
Code
BIDS-90567
Information
RECTANGULAR-RECTANGULAR ANTI-VIBRATION FLANGE FOR STORM

MANUFACTURING FEATURES

• Rectangular-rectangular coupling flange through anti-vibration canvas.
• Supplied with four L-shaped plates made of galvanized sheet metal and necessary screws.

Model
SFC 400 III 93A **
Code
SFC400III93
Information
FREQUENCY SPEED CONTROLLER

MANUFACTURING FEATURES

• Specially designed for speed frequency control in ventilation applications.
• Ultra compact, simple operation and wide range of functions.

*Dial panel incorporated. Optional EMC filter.

Certifications: CE/UL/CSA/EN/GOST/CCC.

Protection index IP20.

The selection of SFC frequency drive speed controller must be made based on the maximum intensity absorbed by the fan to be regulated. The powers (kW) and the intensity for constant load refer to the normal duty (150% overload for 60 seconds). The intensity for quadratic load admits an overload of 110% during 60s.

SFC 230: Entrance 230V I, exit 230V III
SFC 400: Entrance 400V III, exit 400V III

EMC filter incorporated for models from 47A (included)

*Lineal load rated current

**Quadratic load rated current

Model
INT 100 3P A
Code
INT1003PA
Information
SAFETY SWITCH

MANUFACTURING FEATURES

• Safety start-stop switches according to IEC 60947-1 and IEC 60947-3.
• IP65 and always equipped an auxiliary contact.
• Useful for switching off the current before handling the fan.

*Máx. thermal current air (A)

Model
AVR (GENERIC)
Code
Information
ANTI-VIBRATION RUBBER BLOCK

MANUFACTURING FEATURES

• Support of great radial and axial elasticity.
• These low-profile, compact and elastic supports control the three directions of movement with large deformations in the rubber.
• It consists of two parallel armour adhered to the bell-shaped rubber and by a base with handles.
• These supports with handles have a threaded hole in their upper frame and are easy to install and fix.
• The steel protection washer allows it to withstand overloads by increasing its rigidity and protects the rubber from dripping hydrocarbons.
• Elastomer type NR or high quality elastomer. Working temperatures between -40ºC and + 70º C.
• Taking into account the tolerances of hardness in the elastomers, the mechanical characteristics of these series may differ.
• Range of 6 sizes and 3 different hardnesses (45-60-75) to fit a load range between 2 Kg and 1300 Kg.
      1. Soft: hardness A 45
      2. Average: hardness B 60
      3. Hard: hardness C 75

APPLICATIONS

• Very appropriate in the elastic suspensions of machines that present vibrations of horizontal components.

Model
AVS (GENERIC)
Code
Information
ANTI-VIBRATION SPRING BLOCK

MANUFACTURING FEATURES

• Metal insulators designed to work with compression with 85% insulation according to the following arrows (travel in mm) and rpm:

Arrow (mm.)          r.p.m.
    20 mm          >600 r.p.m.
    30 mm          >500 r.p.m.

• Made of high quality elastic steel, with rectangular base and rubber mat to improve the grip. It treats of a resistant product and easy assembly, that avoids all type of vibrations of the fans to the structure of the premises.
• Operating temperature from -45 ° C to + 120 ° C.

APPLICATION

• To install under machines with rotating components, ventilation groups, fans, ventilation boxes, etc.

Model
AB (GENERIC)
Code
Information
ACOUSTIC CABINS FOR CENTRIFUGAL FANS

Structure made of extruded aluminum profiles available in different dimensions according to the panel to be installed and the fan volume. The profiles joining is made of polyamide corners, which gives them great strength and the possibility of disassembling the structure into pieces.

Panels can be made of a single sheet with inner insulation of 10 mm thick polyethylene foam, or 2 sheets (sandwich panel) with thicknesses of 25 mm or 50 mm, depending on the required attenuation degree.

The sheets of each panel can be galvanized steel, galvanized steel with coloured plastic coating or stainless steel.

The lower part is finished off with a structure / plinth for transport and handling, made of galvanized sheet or upn-80/100 joist, depending on the cabin dimensions and weight.

The air inlets and outlets of the cabin have anti-vibration tarpaulins coupled to mounted fans. These fans rest on a floating base with acoustic dampers.

RRP to consult.

Model
CPD-N90
Code
A-CPD-N90
Information
FRONTAL FEET SUPORT

Frontal support for fans NIMUS NIMAX or IGNÉO

For mounting positions LG/RD0, LG/RD90 and LG/RD270

Models of size 500 and above are supplied with a front support foot, for the other models the front support foot is optional.

Made of steel with polyester resin powder coating.

Model
CPDMP-N90
Code
A-CPDMP-N90
Information
MULTIPOSITION FRONTAL FEET SUPPORT

Frontal support for fans NIMUS NIMAX or IGNÉO

For mounting all available positions

Models of size 500 and above are supplied with a front support foot, for the other models the front support foot is optional.

Made of steel with polyester resin powder coating.

NIMUS 901 T4 45kW (std)

Spare parts scheme
Code Family Name Qty
1 R-BAD-N90 INLET CONE 900 x1
2 721001260WEG6 MOTOR 2,2kW T6 B3 230/400V 60Hz x1
3 R-CTB-N901-60BLG TURBINE NIMUS 901 D60 B LG x1