fan image
Model
KENTALCOOK 400 T4 1,1kW
Code
249404206Q

KENTALCOOK 400 T4 1,1kW

VENTILATION BOX WITH REACTION IMPELLER

MANUFACTURING CHARACTERISTICS:
• Watertight ventilation box with very high efficiency and low noise level with 30 mm aluminum profile structure, nylon corners and galvanized steel sandwich panel with internal rock wool insulation 25 mm thick class A1 (non-combustible) and 90 kg/m3 density. All panels have a "fastening system" for easy assembly and disassembly whenever required, whether for cleaning, maintenance or panel exchange.
• Centrifugal fan with motor coupled directly to the coil type plug fan with motor outside the air flow
• Circular inlet to facilitate the connection of ducts. open outlet.
• Models with AC motor isolated from the air flow, which allows working stably with contaminated flow at temperatures higher than ambient. Standard asynchronous squirrel cage motor with IP-55 protection and Class F insulation. Standard voltages 230V 60Hz for single-phase and motors, 230/400-460V for single-speed motors up to 4kW and 400-460/690V60Hz for higher powers and 400V three-phase motors 60Hz for the 2 speeds
•High-performance single-aspiration turbine with backward curved blades (reaction) with self-cleaning system built in steel. Statically and dynamically balanced at origin.
•With stainless steel drainage purge for escape route of the fluid load.
• Built-in safety switch.
• Interchangeable drive panels.
• Registration panel accessible by handle

APPLICATIONS:

Designed for 90º entry-exit installation, they are suitable for:
• Air renewal in buildings and industries.
• Smoke extraction.
• Kitchen extraction.
• Designed to deal with environments with oily load.
•Maximum continuous working temperature: three-phase 120ºC.

Fan

Max flow
6430 m³/h
Weight
61 Kg

Motor

Power
1,1 kW
RPM Motor
1670
I max. 230 V
4,33
I max. 400 V
2,49
Size
90L
Weight
23 Kg
Efficiency
87.8 %
FP
0.78
KENTALCOOK 400 T4 1,1kW
Loading...
Design point
Loading...
Service point
Loading...
Alternative point

KENTALCOOK 400 T4 1,1kW

Dimensions scheme
A B C D F G I
730 730 670 448 792 420 842

KENTALCOOK 400 T4 1,1kW

Electrical scheme

KENTALCOOK 400 T4 1,1kW

Model
SFC 230 I 7A *
Code
SFC230I007
Information
FREQUENCY SPEED CONTROLLER

MANUFACTURING FEATURES

• Specially designed for speed frequency control in ventilation applications.
• Ultra compact, simple operation and wide range of functions.

*Dial panel incorporated. Optional EMC filter.

Certifications: CE/UL/CSA/EN/GOST/CCC.

Protection index IP20.

The selection of SFC frequency drive speed controller must be made based on the maximum intensity absorbed by the fan to be regulated. The powers (kW) and the intensity for constant load refer to the normal duty (150% overload for 60 seconds). The intensity for quadratic load admits an overload of 110% during 60s.

SFC 230: Entrance 230V I, exit 230V III
SFC 400: Entrance 400V III, exit 400V III

EMC filter incorporated for models from 47A (included)

*Lineal load rated current

**Quadratic load rated current

Model
SFC 400 III 3,6A *
Code
SFC400III4
Information
FREQUENCY SPEED CONTROLLER

MANUFACTURING FEATURES

• Specially designed for speed frequency control in ventilation applications.
• Ultra compact, simple operation and wide range of functions.

*Dial panel incorporated. Optional EMC filter.

Certifications: CE/UL/CSA/EN/GOST/CCC.

Protection index IP20.

The selection of SFC frequency drive speed controller must be made based on the maximum intensity absorbed by the fan to be regulated. The powers (kW) and the intensity for constant load refer to the normal duty (150% overload for 60 seconds). The intensity for quadratic load admits an overload of 110% during 60s.

SFC 230: Entrance 230V I, exit 230V III
SFC 400: Entrance 400V III, exit 400V III

EMC filter incorporated for models from 47A (included)

*Lineal load rated current

**Quadratic load rated current

Model
TIC KENTALBOX PLUS/KENTALCOOK 400
Code
A-TICKBP400
Information
OUTLET BLIND COVER FOR KENTALBOX PLUS

MANUFACTURING FEATURES
• Allows customization of outlet’s position and shape.
• Made of galvanized steel.

Model
TBIC KENTALBOX PLUS/KENTALCOOK 400
Code
TBICKBP400
Information
OUTLET ROUND COVER FOR KENTALBOX PLUS

MANUFACTURING FEATURES
• Allows duct connection.
• Made of galvanized steel.

Model
BOX FILTER 730x730x300
Code
BFKENBP400
Information
EXTERNAL BOX FILTER

MANUFACTURING FEATURES

• Structure in aluminum profile 30mm, nylon corners, galvanized sandwich panels with internal insulation rockwool (25mm thickness) class A1 (non-combustible) of 90kg/m3 density
• All panels are equipped with "fastening system" for the quick assembly and disassembly whenever required, either for cleaning, maintenance or exchanging of panels.
• Box is supplied without filters.

(Check the filter units needed for the drawer surface, BOX FILTER for KENTALBOX PLUS need 2 filter of each granulometry)

Model
FILT ISO Coarse≥60% (620x334x48) PREFILTRO MARCO FIBERPLAST
Code
FILTG04050
Information
FILTER CELLS WITH FIBERPLAST FRAME

Filter cells for rough primary filtration for air treatment units

High filtration area, light filter, rigid and easy to compact. 100% Incinerable and water repellent

Media: synthetic thermo pleated
FiberPlast frame

Maximum temperature in continuos service: 70ºC
Humidity 100%HC

Tested for food contact according to CE 1935/2004

Model
FILT ePM1≥50% (620x334x48) ALTA EFIC. PANEL MINIPLEGADO
Code
FILTF07065
Information
HIGH EFFICIENCY, RIGID AND COMPACT FILTER

Filtration for air treatment units equipped with a pre-filter upstream, and air-conditioning units.

High filtration area, high efficiency, compact and economic filter.

Media: Mini pleat fiberglass paper
Frame: Galvanized steel

Maximum T° in continuous service: 100°C
Humidity: 100% RH

Tested for food contact according to CE 1935/2004
Certified for microbial development (ISO 846-VD 6022)

Model
FILT ePM1≥80% (620x334x48) ALTA EFIC. PANEL MINIPLEGADO
Code
FILTF09053
Information
HIGH EFFICIENCY, RIGID AND COMPACT FILTER

Filtration for air treatment units equipped with a pre-filter upstream, and air-conditioning units.

High filtration area, high efficiency, compact and economic filter.

Media: Mini pleat fiberglass paper
Frame: Galvanized steel

Maximum T° in continuous service: 100°C
Humidity: 100% RH

Tested for food contact according to CE 1935/2004
Certified for microbial development (ISO 846-VD 6022)

Model
TEJ KENTALBOX PLUS/KENTALCOOK 400
Code
A-TEJKBP400
Information
WEATHER PROTECTIVE ROOF FOR KENTALBOX PLUS

Weather protective roof made of galvanized steel for KENTALBOX PLUS

Model
FAT TRAP
Code
509129000
Information
STAINLESS STEEL GREASE BOX FOR RESTAURANT EXHAUST FAN

MANUFACTURING FEATURES

  • Grease box for kitchen centrifugal exhaust fan, with drain tube included.
  • Prevents grease buildup on rooftop.
  • Made of stainless steel with sprayed surface.
  • Meets the NFPA requirement.


IMPORTANT

The fan must be elevated above the ground or roof to be able to install the FAT TRAP box.

 

KENTALCOOK 400 T4 1,1kW

Spare parts scheme
Code Family Name Qty
1 721001152WEG6 MOTOR 1,1kW T4 B5 230/400V 60Hz x1
2 R-R63D1L400-24 TURBINE R63D1L400x112x24 LG x1
3 R-BAD400PK1 INLET CONE ED11P 400 x1
4 INT253PA SAFETY SWITCH INT 25 3P A x1