fan image
Model
KASTORM 401 T2 7,5kW ATEX Zone 2: FAN (Ex h IIB T3 Gc) + MOTOR (Ex ec IIC T3 Gc)
Code
PSCU40121326XN

KASTORM 401 T2 7,5kW ATEX Zone 2: FAN (Ex h IIB T3 Gc) + MOTOR (Ex ec IIC T3 Gc)

MEDIUM PRESSURE OF SIMPLE ASPIRATION AND DIRECT COUPLING. ROBUST, COMPACT AND CUBIC ATEX


MANUFACTURING FEATURES


• Reinforced cubic housing made of carbon laminated steel, protected against corrosion by powder coating of RAL 5010 polyester resin. C3 finish.
• Self-cleaning turbine and reinforced impeller of high-performance backward blades made of carbon laminated steel dynamically balanced to minimize noise and vibrations. Painted black RAL 9005.
• Standardized asynchronous squirrel cage motor with IP-55 protection and class F electrical isolation. Standard voltages 230/400V 60Hz for three-phase motors up to 4kW and 400/690V 60Hz for higher powers.
• Motor with flange (B5) and waterproof shaft.
• Welded Cubic Housing .
• Working temperature: ambient from -20ºC to 40ºC, transported air according to the ATEX clasification.

• Available positions (to be indicated in case of order, to maintain the connection box on the top): LG270, LG0, LG90, LG180. RD 270, RD0, RD90, RD180.
• The indicated codes correspond to the model in position LG270

APPLICATIONS
Suitable for moving clean or dusty air. Designed to be installed in conduit for suction or impulsion.
• Paint booths
• Dust Collection
• Food industry dryers
• Food processing
• Incineration
• Odor control in industry
• Indoor / outdoor pollution control
• Big buildings
• Malls
• Factories / Industrial buildings
• Warehouses
• Smoke extraction
• Boilers and ovens
• Manufacture and treatment of chemical products
• Tunnels, underground stations

UNDER REQUEST
• Fans for special voltages.
• 2 speed motor.
• 6-pole motor.
• Inox 304 (normal or electropolished finish)
• Inox 316 (normal or electropolished finish)
• Inspection door for easy maintenance and cleaning
• Sewer system

Fan

Max flow
11590 m³/h
Weight
94.33 Kg

Motor

Power
7,5 kW
RPM Motor
3492
I max. 400 V
14,1
I max. 690 V
8,17
Size
132S
Weight
73 Kg
Efficiency
89.1 %
FP
0.87
KASTORM 401 T2 7,5kW ATEX Zone 2: FAN (Ex h IIB T3 Gc) + MOTOR (Ex ec IIC T3 Gc)
Loading...
Design point
Loading...
Service point
Loading...
Alternative point

KASTORM 401 T2 7,5kW ATEX Zone 2: FAN (Ex h IIB T3 Gc) + MOTOR (Ex ec IIC T3 Gc)

Dimensions scheme
A B C (±) D E F G H I J M N O P Q S T U V W X
693.4 824.2 714.3 438 294.3 8x45º 22,5º 493 332 302 252 400 302 332 106 120 120 360 450 704.2 480

KASTORM 401 T2 7,5kW ATEX Zone 2: FAN (Ex h IIB T3 Gc) + MOTOR (Ex ec IIC T3 Gc)

Electrical scheme

KASTORM 401 T2 7,5kW ATEX

Model
RA 40/16
Code
A-253511901
Information
INLET PROTECTION GUARD FOR CENTRIFUGAL FANS

MANUFACTURING FRATURES

• Inlet protection guard to avoid the entry of objects and contact with the impeller.
• Made of galvanised steel models 7,9, 10, 12 and 15. And the rest of models with polyester powder finishing coat.

Model
AC 400
Code
960003212
Information
CONECTION FLANGE

MANUFACTURING FEATURES

• For axial (inlet and outlet) and centrifugal (inlet) fans.

UNDER REQUEST

• Versions in stainless 304 and stainless 316.

Model
JE 45
Code
A-300719201
Information
ANTI-VIBRATION JOINT

MANUFACTURING FEATURES

• Flexible joint to clinch the fan to the duct.
• Avoids transmission of vibrations for circular and rectangular connection.
• Dimensions: two metallic flanges of 45mm each one and a flexible flange of 60mm.
• The reel is 30,5m lenght.
• Maximum pressure: 20 mmca.
• Fire resistance M0 from -50ºC to +200ºC in continuous and 400ºC/2h.

Model
EIS 400x252-400
Code
EIS-4025240
Information
OUTLET FLANGE FOR STORM MODELS

MANUFACTURING FEATURES

• Connection flange for rectangular outlet of STORM centrifugal fans making the connection to circular duct easier.
• Manufactured in galvanized steel.

UNDER REQUEST

• Versions in stainless 304 and stainless 316.

Model
RIS 400x252
Code
RIS-40252E2
Information
OUTLET PROTECTION GUARD FOR STORM FANS

MANUFACTURING FRATURES

• Protective grid for outlet installation in STORM medium pressure fans.
• Made of rolling steel sheet, protected against corrosion by powder coating of polyester resin.

*The Storm fan can be a NIMUS, NIMAX, PRESTUR, PREXTUR or IGNÉO

Model
CPS 400x252-400
Code
CPS-4025240
Information
OUTLET BEND FOR STORM FANS

MANUFACTURING FEATURES

• Manufactured in galvanized steel sheet for circular-rectangular adaptation.

APPLICATIONS

• 90º bend for vertical discharge, often needed in oaint booths.

UNDER REQUEST

• Painted.
• Inox 304 and Inox 316.

Model
BADS ATEX 400
Code
BADS-4040X0
Information
CIRCULAR-CIRCULAR COUPLING FLANGE ATEX FOR STORM

MANUFACTURING FEATURES

• Circular-circular coupling flange through anti-vibration canvas ATEX.
• Supplied with two O-shaped plates made of galvanized sheet metal and necessary screws.

Model
BIDS ATEX 252x400-200
Code
BIDS-40252X0
Information
RECTANGULAR-RECTANGULAR COUPLING FLANGE ATEX FOR STORM

MANUFACTURING FEATURES

• Rectangular-rectangular coupling flange through anti-vibration canvas ATEX.
• Supplied with four L-shaped plates made of galvanized sheet metal and necessary screws.

Model
INT 25 ATEX
Code
510200025X
Information
ATEX SWITCH

Switch for ATEX environments. Suitable for zones 1-2 (gas) and 21-22 (dust), index protection IP65. Manufactured in aluminum alloy and RAL 7000 gray finishing coat. External screws in stainless steel. Control on the front. Tensions up to 690V. According to directive 2014/34 / UE (ATEX).

Model
SFC 400 III 16A *
Code
SFC400III16
Information
FREQUENCY SPEED CONTROLLER

MANUFACTURING FEATURES

• Specially designed for speed frequency control in ventilation applications.
• Ultra compact, simple operation and wide range of functions.

*Dial panel incorporated. Optional EMC filter.

Certifications: CE/UL/CSA/EN/GOST/CCC.

Protection index IP20.

The selection of SFC frequency drive speed controller must be made based on the maximum intensity absorbed by the fan to be regulated. The powers (kW) and the intensity for constant load refer to the normal duty (150% overload for 60 seconds). The intensity for quadratic load admits an overload of 110% during 60s.

SFC 230: Entrance 230V I, exit 230V III
SFC 400: Entrance 400V III, exit 400V III

EMC filter incorporated for models from 47A (included)

*Lineal load rated current

**Quadratic load rated current

Model
AVR (GENERIC)
Code
Information
ANTI-VIBRATION RUBBER BLOCK

MANUFACTURING FEATURES

• Support of great radial and axial elasticity.
• These low-profile, compact and elastic supports control the three directions of movement with large deformations in the rubber.
• It consists of two parallel armour adhered to the bell-shaped rubber and by a base with handles.
• These supports with handles have a threaded hole in their upper frame and are easy to install and fix.
• The steel protection washer allows it to withstand overloads by increasing its rigidity and protects the rubber from dripping hydrocarbons.
• Elastomer type NR or high quality elastomer. Working temperatures between -40ºC and + 70º C.
• Taking into account the tolerances of hardness in the elastomers, the mechanical characteristics of these series may differ.
• Range of 6 sizes and 3 different hardnesses (45-60-75) to fit a load range between 2 Kg and 1300 Kg.
      1. Soft: hardness A 45
      2. Average: hardness B 60
      3. Hard: hardness C 75

APPLICATIONS

• Very appropriate in the elastic suspensions of machines that present vibrations of horizontal components.

Model
AVS (GENERIC)
Code
Information
ANTI-VIBRATION SPRING BLOCK

MANUFACTURING FEATURES

• Metal insulators designed to work with compression with 85% insulation according to the following arrows (travel in mm) and rpm:

Arrow (mm.)          r.p.m.
    20 mm          >600 r.p.m.
    30 mm          >500 r.p.m.

• Made of high quality elastic steel, with rectangular base and rubber mat to improve the grip. It treats of a resistant product and easy assembly, that avoids all type of vibrations of the fans to the structure of the premises.
• Operating temperature from -45 ° C to + 120 ° C.

APPLICATION

• To install under machines with rotating components, ventilation groups, fans, ventilation boxes, etc.

Model
AB (GENERIC)
Code
Information
ACOUSTIC CABINS FOR CENTRIFUGAL FANS

Structure made of extruded aluminum profiles available in different dimensions according to the panel to be installed and the fan volume. The profiles joining is made of polyamide corners, which gives them great strength and the possibility of disassembling the structure into pieces.

Panels can be made of a single sheet with inner insulation of 10 mm thick polyethylene foam, or 2 sheets (sandwich panel) with thicknesses of 25 mm or 50 mm, depending on the required attenuation degree.

The sheets of each panel can be galvanized steel, galvanized steel with coloured plastic coating or stainless steel.

The lower part is finished off with a structure / plinth for transport and handling, made of galvanized sheet or upn-80/100 joist, depending on the cabin dimensions and weight.

The air inlets and outlets of the cabin have anti-vibration tarpaulins coupled to mounted fans. These fans rest on a floating base with acoustic dampers.

RRP to consult.

KASTORM 401 T2 7,5kW ATEX Zone 2: FAN (Ex h IIB T3 Gc) + MOTOR (Ex ec IIC T3 Gc)