HMR EVO
Model
HMR EVO 560 T6 1,5kW
Code
261561663

HMR EVO 560 T6 1,5kW

LONG CASE FAN WITH BACKWARD IMPELLER

MANUFACTURING FEATURES:

• Reinforced fan casing manufactured in rolling steel sheet. Polyester powder finishing coat. Housing with motor access door.
• High efficiency backward impeller with self-cleaning system in steel sheet, balanced static and dynamically in origin.High efficiency impeller with built-in diffuser, which eliminates the need to use a scroll or spiral casing to obtain performance.
• Models with AC motor inside the air flow. Standard asynchronous squirrel cage motor with IP-55 protection and Class F insulation. Standard voltages of 230V 60Hz for single phase motors, 230/400V 60Hz & 400/690V 60Hzfor three-phase 1 speed motors and 400V 60Hz for 2 speed motors.

• Maximum working temperature 60ºC.

APPLICATIONS:

Designed for inline installation, they are suitable for:
• Air renewal in buildings and industries.
• Smoke extraction.

Fan

Max flow
10080 m³/h
Weight
120 Kg

Motor

Power
1,5 kW
RPM Motor
1128
I max. 230 V
6,45
I max. 400 V
3,71
Size
100L
Weight
28 Kg
Efficiency
86.8 %
FP
0.73
HMR EVO 560 T6 1,5kW
Loading...
Design point
Loading...
Service point
Loading...
Alternative point

HMR EVO 560 T6 1,5kW

Dimensions scheme
A B C D F G H
964.5 883.5 908.5 628 1000 970 Ø12x16

HMR EVO 560 T6 1,5kW

Electrical scheme

HMR EVO 560 T6 1,5kW

Model
INT 25 3P A
Code
INT253PA
Information
SAFETY SWITCH

MANUFACTURING FEATURES

• Safety start-stop switches according to IEC 60947-1 and IEC 60947-3.
• IP65 and always equipped an auxiliary contact.
• Useful for switching off the current before handling the fan.

*Máx. thermal current air (A)

Model
RP 63
Code
960330101
Information
PROTECTION GUARD FOR LONG CASE FANS

CONSTRUCTION FEATURES

• Protective grille on the motor and propeller side to prevent objects from entering. For HC and HCA models, the RP grille is only applicable on the propeller side. The RP is also suitable for the HMR EVO range, both for intake and discharge (note that the grille is of different sizes depending on whether it is for intake or discharge)
• Constructed with electro-welded rod.
• Compliant with ROHS directive 2002/95/EC.

ON REQUEST

• Grille in 304 or 316 stainless steel with electropolished finish.

Model
RP 90
Code
960340102
Information
PROTECTION GUARD FOR LONG CASE FANS

CONSTRUCTION FEATURES

• Protective grille on the motor and propeller side to prevent objects from entering. For HC and HCA models, the RP grille is only applicable on the propeller side. The RP is also suitable for the HMR EVO range, both for intake and discharge (note that the grille is of different sizes depending on whether it is for intake or discharge)
• Constructed with electro-welded rod.
• Compliant with ROHS directive 2002/95/EC.

ON REQUEST

• Grille in 304 or 316 stainless steel with electropolished finish.

Model
PO 90
Code
960001661
Information
CASE FANS MOUNTING SUPPORT

MANUFACTURING FEATURES

• Made of steel and protected against corrosion with polyester resin powder.

Model
SFC 230 I 7A *
Code
SFC230I007
Information
FREQUENCY SPEED CONTROLLER

MANUFACTURING FEATURES

• Specially designed for speed frequency control in ventilation applications.
• Ultra compact, simple operation and wide range of functions.

*Dial panel incorporated. Optional EMC filter.

Certifications: CE/UL/CSA/EN/GOST/CCC.

Protection index IP20.

The selection of SFC frequency drive speed controller must be made based on the maximum intensity absorbed by the fan to be regulated. The powers (kW) and the intensity for constant load refer to the normal duty (150% overload for 60 seconds). The intensity for quadratic load admits an overload of 110% during 60s.

SFC 230: Entrance 230V I, exit 230V III
SFC 400: Entrance 400V III, exit 400V III

EMC filter incorporated for models from 47A (included)

*Lineal load rated current

**Quadratic load rated current

Model
SFC 400 III 5A *
Code
SFC400III5
Information
FREQUENCY SPEED CONTROLLER

MANUFACTURING FEATURES

• Specially designed for speed frequency control in ventilation applications.
• Ultra compact, simple operation and wide range of functions.

*Dial panel incorporated. Optional EMC filter.

Certifications: CE/UL/CSA/EN/GOST/CCC.

Protection index IP20.

The selection of SFC frequency drive speed controller must be made based on the maximum intensity absorbed by the fan to be regulated. The powers (kW) and the intensity for constant load refer to the normal duty (150% overload for 60 seconds). The intensity for quadratic load admits an overload of 110% during 60s.

SFC 230: Entrance 230V I, exit 230V III
SFC 400: Entrance 400V III, exit 400V III

EMC filter incorporated for models from 47A (included)

*Lineal load rated current

**Quadratic load rated current

Model
DBIC HMR 560
Code
261900100
Information
CIRCULAR OUTLET DISC

The DBIC for HMR EVO is suitble for installing circular ducts on the oulet

Made of galvanized steel

HMR EVO 560 T6 1,5kW

Spare parts scheme
Code Family Name Qty
1 721001254WEG6 MOTOR 1,5kW T6 B3 230/400V 60Hz x1
2 R-R63D1L560-28 TURBINE R63D1L560x160x28 LG x1
3 R-BAD560PK1 INLET CONE ED11P 560 x1