fan image
Model
KRISONA 40 EEC DUO
Code
KRISEC40D

KRISONA 40 EEC DUO

WALL DESCENTRALIZED RESIDENTIAL RECOVERY UNIT WITH WIRED REMOTE CONTROL

MANUFACTURING FEATURES
•  Decentralized  residential  recovery unit  for single-stack use in combination with a remote control (available as an accessory), connected by cable, wall-mounted and flush-mounted.
•  Designed  to  minimize the  aesthetic  impact  of the installed product, they are characterized  by a particularly low-thickness wall frame (only 17 mm).
•  Ultra low power  consumption (2.8W to  8.6W ), perfectly compatible  with 24/7 operation.
• VMC unit for a single room, with alternating flows, with a very high efficiency heat recovery unit (up to 90%) and a ceramic exchanger cell in the form of a honeycomb.
• Fans with EC motor, to guarantee very low consumption,  driven by low voltage  and with shafts mounted on ball bearings.
• Extremely low noise levels, compatible  with installation  in living rooms  (living room, study, bedroom) and use at night.
• Ventilation duct with damping mechanism, to avoid the risk of contaminants entering from the outside and to maximize thermal insulation in the event that the room is not occupied for long periods.
• Possibility of installation on exterior walls with a thickness between 300 mm and 700 mm (with optional accessory).
• Operation permitted in a wide range of outdoor temperatures (-20°/50°C).
• Degree of protection against dust and water: IPX4.
• Electrical  insulation class: II (ground  connection is not required).
• The remote control can manage up to a total of 6 decentralized recuperators.

SOME CONTROL FUNCTIONS

Using the remote control (must be ordered separately) you can access the following options:
•    Selection of 3 operating modes: Heat recovery, normal ventilation without heat recovery, and air extraction.
•    Speed Selection
•    Boost speed
•    Filter status LED indicator: off for clean filters and on if filters are dirty and need to be replaced.

APPLICATIONS
• Decentralized ventilation unit with heat recovery specifically designed for air exchange  in residential spaces characterized  by high levels of thermal insulation.
• For rooms up to 20m² for each recovery unit.

Fan

Max flow
41 m³/h
Weight
2.55 Kg

Motor

Power
0,0055 kW
RPM Motor
-
I max. 230 V
0,05
KRISONA 40 EEC DUO
Loading...
Design point
Loading...
Service point
Loading...
Alternative point

KRISONA 40 EEC DUO

Dimensions scheme
A B C D E F G H ØI ØJ ØK ØL
240 224 80 64 17 275 42 18 151 146 153 216

KRISONA 40 EEC DUO

Electrical scheme

KRISONA 40 EEC DUO

Model
KRISONA CTRL-DUO
Code
CTRLKRISECD
Information
KRISONA CTRL-DUO

• The control can manage up to a total of 6 decentralized recovery units.
• In VENTILATION or RECOVERY modes, the recovery units will start to ensure the balance of the general flow in ventilation mode with heat recovery.

Heat recovery mode
• Winter: Extracted air from the room (hot) is exploited to pre-heating the air supplied to the room (cold).
• Summer: Extracted air from the room (cold) is exploited to pre-cooling the air supplied to the room (hot).
• The connected devices cyclically reverse the direction of fan rotation (extracting and introducing air into the environment) with a set cycle time.
• Speed adjustment (of devices) is automatic and ensures the correct ba-lance of the Input/Output flow rates.

Ventilation Mode
• The devices change internal environment air (without recovering heat).
- Even number devices extract air from the environment.
- Odd number devices introduce air into the environment.
• Speed adjustment (of devices) is automatic and ensures the correct ba-lance of the Input/Output flow rates.

Air Extraction Mode
• All connected devices extract air from the internal environment.
• The air flow rates are all in Output toward the external environment.

Model
RPS (24W)
Code
RPS24
Information
POWER SUPPLY

Input 230Vac 50/60Hz (N=Blue, L= Brown)
Output: 12 Vdc-2A 24W (+=Red, -= Black)

 

 

Working temperature: -10ºC/50ºC

Model
SPS (36W)
Code
SPS36
Information
FUENTE DE ALIMENTACIÓN

Input 230Vac 50/60Hz (N=Blue, L= Brown)
Output: 12 Vdc-3A 36W (+=red, -= Black)

Working temperature: -10ºC/50ºC

Model
SPS-DIN (36W DIN)
Code
SPSDIN36
Information
POWER SUPPLY FOR DIN

Input 100-240Vrms 50/60Hz
Output: 12 Vdc-3A 36W

Working temperature: -10ºC/50ºC

Model
FPC (Ferrita)
Code
FPC300
Information
FERRITA

Ferrita for wiring

Model
TB
Code
TB1670
Information
RIGID PVC PIPE FOR KRISONA EEC

Rigid PVC pipe (diameter 160 and length 700 mm) for wall mounting.

Model
PM
Code
PM316323
Information
METAL PANEL FOR KRISONA EEC

Metal panel “windbreak” for exterior in stainless steel sheet.

Model
REP
Code
REP260
Information
EXTERNAL RUBBER GRILL FOR KRISONA EEC

External rubber grille that can be installed from the inside wthi out the need for scaffolding.
 

Model
ACC
Code
ACC90
Information
CIRCULAR-RECTANGULAR ADAPTER FOR KRISONA EEC

90° Circular / Square Adapter for entry and exit through a window jamb.

Model
RINOX
Code
RINOXAAC
Information
RECTANGULAR STAINLESS STEEL GRILL FOR KRISONA EEC

Rectangular stainless steel grill for ACC window adapter kit 

Model
RINOXBACC
Code
RINOXBAAC
Information
RECTANGULAR GRID FOR KRISONA EEC

Rectangular grid in powder-coated stainless steel, white RAL 9003, for kit.

Model
STEMP
Code
STEMP3A
Information
SENSOR TO CONTROL THE AIR TEMPERATURE

Sensor to control the air temperature in the room: allows automatic start or speed change of the combined product when the temperature exceeds the preset value, selectable by external trimmer and adjustable in the range 10°C - 40°C. A timer allows the appliance to operate for a predetermined time, which can be set during installation from 3 to 20 minutes, after the temperature has dropped below the predetermined threshold.
Single-phase 220-240V / 50- 60 Hz power supply. Wall installation.
The color white.
Maximum allowable load: 3A.
Enclosure for wall installation with IP20 protection.

Model
SHR
Code
SHR3A
Information
SENSOR TO CONTROL THE RATE OF RELATIVE HUMIDITY

Sensor for controlling the rate of relative humidity (RH) in the air: allows automatic start or speed switching of the combined product when the percentage of RH exceeds 65%. If the humidity does not exceed the threshold, the associated appliance turns on automatically a few seconds after the light is turned on and continues to operate, after it is turned off, for a preset time, which can be set during installation from 3 to 20 minutes .
Single-phase power supply 220-240 V / 50-60 Hz. Wall installation. The color white.
Maximum admissible load: 3 A.
Enclosure for wall installation with IP20 protection.
Sensor para el control de la tasa de humedad relativa