RESIDENTIAL HEAT RECOVERY UNIT WITH EC MOTOR FOR FALSE CEILING
MANUFACTURING FEATURES
• Dual flow centralized ventilation unit with heat recovery for false ceiling installation.
• It is characterized by high levels of thermal insulation.
• Version equipped with HR sensor, for automatic management of operating speed.
• Black painted sheet steel housing, including brac- kets for fixing fasteners, in galvanized sheet steel, supplied as standard and required for suspended installation of the appliance. Internal details in expanded polypropylene (PPE) that integrate the connection ports to the extraction and supply pipes with a nominal diameter of 100 and 125 mm. The panels at the bottom of the product provide
nents (fans, heat exchanger, electronic package and network connection terminal block).
• Plastic resin condensate collection tank, connected to the heat exchanger and complete with the condensation overflow sensor.
• Pair of centrifugal fans powered by 3-speed EC (brushless) motors, adjustable regardless of speed.
• Counter-current cross-flow heat exchanger.
• Mechanical bypass, 100% filtered, with automatic actuation.
• Advanced electronic package, easily accessible even when the product is already installed for initial configurations and subsequent maintenance interventions.
• Two ISO COARSE ≥ 50% (G3) filters, placed in correspondence with the extraction and supply lines (optional ISO COARSE ≥ 60% (G4) filters are available for the extraction channel, ISO ePM10 ≥ 50% (M5),
ISO ePM1 ≥ 50% (F7) and ISO ePM1 ≥ 80% (F9) for the
supply channel).
• Wired control supplied with the recovery unit.
SOME CONTROL FUNCTIONS
• Configuration, at installation, of the product’s operating parameters (fan speed, relative humidity threshold, etc.)
• Automatic bypass management.
• Heat exchanger frost protection.
• Monitoring of the clogging status of the filters and signaling of the need for cleaning/maintenance by means of an optical signal on the control display.
APPLICATIONS
• Specifically designed for ventilation of small apartments and offices, residences and hotel rooms, with an area of up to 80 m2.
A | B | C | D | E | F | G | H | I | J | K | L | M |
---|---|---|---|---|---|---|---|---|---|---|---|---|
484 | 440.5 | 218 | 40 | 5 | 250 | 158 | 69 | 69 | 92 | 333 | 513 | 361 |
MANUFACTURING FEATURES
• Thermally insulated flexible duct manufactured with inner tube 3 layers of aluminium and 2 layers of polyester.
• Reinforced internally with spiral steel wire. 25mm mineral wool insulation, exterior coating with aluminium and polyester multilayer pipe that works as an optimal vapor barrier and prevents condensation.
• Classification of fire resistance: M1.
• Maximum working pressure: 3000 Pa.
• Working temperature: -30 to 140ºC.
• Maximum speed: 30m/s.
APPLICATION
• In sections of 10 meters for installations of air conditioning, ventilation and VMC systems
MANUFACTURING FEATURES
• Flexible insulated thermo-acoustic tube made with inner tube 3 layers of aluminium and 2 layers of polyester.
• Reinforced internally with spiral steel wire, 25mm mineral wool insulation, exterior coating with aluminium and polyester multilayer pipe that works as an optimal vapor barrier and prevents condensation.
• Maximum working pressure: 2000 Pa.
• Working temperature: -30 to 140ºC.
• Maximum speed: 30m/s.
APPLICATION
• In sections of 10 meters for installations of air conditioning, ventilation and VMC systems.
• Filter for use in fan coil units, air heaters or electrical cabinets.
• Solid execution and great finish.
• Synthetic stocking.
• 4mm diameter galvanized steel rod frame.
• Maximum temperature in continuous service 80ºC.
• Relative humidity 100%
• Approved for contact with food according to CE 1935/2004.
• Filter for use in fan coil units, air heaters or electrical cabinets.
• Solid execution and great finish.
• Synthetic stocking.
• 4mm diameter galvanized steel rod frame.
• Maximum temperature in continuous service 80ºC.
• Relative humidity 100%
• Approved for contact with food according to CE 1935/2004.
Filter cells for rough primary filtration for air treatment units
High filtration area, light filter, rigid and easy to compact. 100% Incinerable and water repellent
Media: synthetic thermo pleated
FiberPlast frame
Maximum temperature in continuos service: 70ºC
Humidity 100%HC
Tested for food contact according to CE 1935/2004
Filtration for air treatment units equipped with a pre-filter upstream, and air-conditioning units.
• High filtration area, high efficiency, compact and economic filter.
• Media: Mini pleat fiberglass paper
• Frame: Galvanized steel
• Maximum T° in continuous service: 100°C
• Humidity: 100% RH
• Tested for food contact according to CE 1935/2004
• Certified for microbial development (ISO 846-VD 6022)
Filtration for air treatment units equipped with a pre-filter upstream, and air-conditioning units.
• High filtration area, high efficiency, compact and economic filter.
• Media: Mini pleat fiberglass paper
• Frame: Galvanized steel
• Maximum T° in continuous service: 100°C
• Humidity: 100% RH
• Tested for food contact according to CE 1935/2004
• Certified for microbial development (ISO 846-VD 6022)
Exterior polypropylene anti-insect grille. Diameter 125.
6-hole distribution plenum.
Semi-flexible circular duct with smooth inner surface made of HDPE (high density polyethylene), double wall. Externally self-extinguishing and internally antistatic.
Anti-extrusion ring.
Plenum box with direct coupling rectangular grid.
Air diffusion grille
Air diffusion grille (for 2 plenums)
Reducing flexible circular duct clamp from 150 to 125mm