fan image
Model
HIDRIDA LP 200 EEC
Code
HIDLP200

HIDRIDA LP 200 EEC

FALSE CEILING HEAT RECOVERY UNITS

MANUFACTURING FEATURES

• Centralized double flow ventilation unit with heat recovery unit for falseceiling installation.The ideal compromise  between performance, functions, purchase and operating costs makes the HIDRIDA LP EEC range the most costeffective solution for the ventilation.
• 2 models, different in size and performance provided.
•  Casings  in  galvanized  steel  sheet   integrating the  support  brackets  for false ceiling mounting; interior shell covered in sound-absorbing and fire-resistant  heat-insulating material (DIN EN 13501). Tie rods for suspended installation included in the standard  equipment.
• Inlet and outlet vents compatible with the combination with tubes with a nominal diameter  of 125 mm (HIDRIDA LP 200 EEC ) and 150 mm (HIDRIDA LP 350 EEC).
•  Pair of fan motors  driven by external  rotor EC (brushless) motors, with shafts mounted on bearings balls, directly coupled  to backward  curved centrifugal  impellers  to  guarantee high  aeraulic efficiency. 3 speeds  of functioning, independently settable at the time of installation.
• High efficiency heat exchanger, cross-flow counter-flow type, made of plastic resin (PS).
• Antifreeze protection with automatic  activation, to prevent the formation of frost at the heat exchanger.
• Thermodynamic, automatic  and 100% filtered by-pass, to guarantee occupant  comfort. Ideal for half seasons, or in any case when the outside temperature does not require the action of the heat exchanger.
• Three-speed control panel supplied can be housed in a 503 box.
• Pair of ISO ePM10 ≥ 50% (M5) filters ISO ePM1 ≥ 50% (F7) filter available as an option for the delivery duct), easily accessible for repairs periodic maintenance.
• Condensate collection tray with drain devices.
• Degree of protection against dust and water: IPX2.
• Class of electrical insulation:II (earthing is not required).

SOME CONTROL FUNCTIONS

• Remote command group, of the  wired connection type, which allows:
•         Switching the product on and off.
•    The choice of the  product’s minimum, average or maximum speed.
•    Signaling, by means of an indicator light, of the condition of saturated filters.

APPLICATIONS
Ventilation of residential and commercial premises of up to 90 m2 (HIDRIDA LP 200 EEC) or 240 m2 (HIDRIDA LP 350 EEC).

UNDER REQUEST
• Possibility of installation  with external  environmental sensors (optional), for the passage  for the automatic control of the operating mode.

Fan

Max flow
206 m³/h
Weight
27 Kg

Motor

Power
0.10199999999999999 kW
RPM Motor
-
I max. 230 V
1
HIDRIDA LP 200 EEC
Loading...
Design point
Loading...
Service point
Loading...
Alternative point

HIDRIDA LP 200 EEC

Dimensions scheme
A B C D E F
969 240 643 860 551 125

HIDRIDA LP 200 EEC

Electrical scheme

HIDRIDA LP 200 EEC

Model
THERMI Ø127
Code
10000602
Information
REINFORCED FLEXIBLE TUBE WITH THERMAL INSULATION OF ALUMINUM

MANUFACTURING FEATURES

• Thermally insulated flexible duct manufactured with inner tube 3 layers of aluminium and 2 layers of polyester.
• Reinforced internally with spiral steel wire. 25mm mineral wool insulation, exterior coating with aluminium and polyester multilayer pipe that works as an optimal vapor barrier and prevents condensation.
• Classification of fire resistance: M1.
• Maximum working pressure: 3000 Pa.
• Working temperature: -30 to 140ºC.
• Maximum speed: 30m/s.

APPLICATION

• In sections of 10 meters for installations of air conditioning, ventilation and VMC systems

Model
PHONI M1 Ø127
Code
10000585
Information
FLEXIBLE WITH THERMAL-ACOUSTIC INSULATION CLASSIFICATION M1 OF FIRE RESISTANCE

MANUFACTURING FEATURES

• Flexible insulated thermo-acoustic tube made with inner tube 3 layers of aluminium and 2 layers of polyester.
• Reinforced internally with spiral steel wire, 25mm mineral wool insulation, exterior coating with aluminium and polyester multilayer pipe that works as an optimal vapor barrier and prevents condensation.
• Maximum working pressure: 2000 Pa.
• Working temperature: -30 to 140ºC.
• Maximum speed: 30m/s.

APPLICATION

• In sections of 10 meters for installations of air conditioning, ventilation and VMC systems.

Model
REP125
Code
REP125
Information
EXTERNAL GRILL FOR HIDRIDA LP EEC O MOOTA LP EEC

Exterior polypropylene anti-insect grille. Diameter 125.

Model
PLEN-6
Code
PLEN-6
Information
PLENUM FOR MOOTA LP EEC, ORMEN EEC OR HIDRIDA LP EEC

6-hole distribution plenum.

Model
HDPE
Code
HDPE
Information
SEMI-FLEXIBLE CIRCULAR DUCT FOR MOOTA LP EEC, ORMEN EEC OR HIDRIDA LP EEC

Semi-flexible circular duct with smooth inner surface made of HDPE (high density polyethylene), double wall. Externally self-extinguishing and internally antistatic.

Model
CON-HDPE
Code
CON
Information
CIRCULAR CONNECTOR FOR HDPE

Circular connector for HDPE conduit

Model
AS-HDPE
Code
AS-HDPE
Information
SEALING RING FOR HDPE AND CON-HDPE

Sealing ring for conduit and connector

Model
AE-HDPE
Code
AE-HDPE
Information
ANTI-EXTRUSION RING FOR HDPE AND CON-HDPE

Anti-extrusion ring.

Model
PLEND
Code
PLEND
Information
PLENUM BOX FOR MOOTA LP EEC OR HIDRIDA LP EEC

Plenum box with direct coupling rectangular grid.

Model
REJD1
Code
REJD193140
Information
AIR DIFFUSION GRILLE FOR PLEND ACCESSORY

Air diffusion grille

Model
REJD3
Code
REJD366140
Information
AIR DIFFUSION GRILLE FOR PLEND ACCESSORY

Air diffusion grille (for 2 plenums)

Model
C-RES
Code
CRES150
Information
CIRCULAR DUCT CLAMP

Reducing flexible circular duct clamp from 150 to 125mm

Model
ECR 500
Code
BE500W
Information
ELECTRICAL COILS FOR HIDRIDA LP EEC AND MOOTA LP EEC

Electrical coil.

Model
ECR 700
Code
BE750W
Information
ELECTRICAL COILS FOR HIDRIDA LP EEC AND MOOTA LP EEC

Electrical coil.

Model
FILT ePM1≥50% (228x224x24) ALTA EFIC. PANEL MINIPLEGADO
Code
FILTF07009
Information
HIGH EFFICIENCY, RIGID AND COMPACT FILTER

Filtration for air treatment units equipped with a pre-filter upstream, and air-conditioning units.

High filtration area, high efficiency, compact and economic filter.

Media: Mini pleat fiberglass paper
Frame: Galvanized steel

Maximum T° in continuous service: 100°C
Humidity: 100% RH

Tested for food contact according to CE 1935/2004
Certified for microbial development (ISO 846-VD 6022)

Model
FILT ePM10≥50% (212x227x24) PREFILTRO MARCO FIBERPLAST
Code
FILTM05001
Information
FILTER CELLS WITH FIBERPLAST FRAME

Filter cells for rough primary filtration for air treatment units

High filtration area, light filter, rigid and easy to compact. 100% Incinerable and water repellent

Media: synthetic thermo pleated
FiberPlast frame

Maximum temperature in continuos service: 70ºC
Humidity 100%HC

Tested for food contact according to CE 1935/2004