fan image
Model
KRISONA 40 EEC
Code
KRISEC40

KRISONA 40 EEC

DESCENTRALIZED RESIDENTIAL RECOVERY UNIT

MANUFACTURING FEATURES
• Decentralized residential recovery unit for singlestay use.
• Can be  installed  on  perimeter   walls between 300mm and 700mm thick. Diameter Ø160 mm for duct.
• Fans with EC motor, to guarantee very low consumption, driven by low voltage, with shafts mounted on ball bearings.
• VMC unit for a single room, with alternating flows, with a very high efficiency heat recovery unit (up to 90%) and a ceramic honeycomb exchanger.
• Filters ISO Coarse≥50% (G3) (ISO ePM10≥50% - M5- optional).
• Degree of protection from dust and water: IPX4.
• Electrical  insulation  class: II  (earthing  is not  required).

SOME CONTROL FUNCTIONS
• Integrated selector with 3 operating modes:
•    Ventilation with heat recovery, air extraction and air supply.
•    Integrated  selector   with   5  adjustable speeds from 18 to 40 m³/h.
•    Integrated led light for filter status: led off for clean filters and led on for dirty filters that need to be replaced.

APPLICATIONS
• Decentralized ventilation unit with heat recovery function, specifically designed for air exchange  in residential  spaces  characterized  by high  levels of thermal insulation.
• For rooms up to 20m².

 

Fan

Max flow
41 m³/h
Weight
2.55 Kg

Motor

Power
0,0055 kW
RPM Motor
-
I max. 230 V
0,05
KRISONA 40 EEC
Loading...
Design point
Loading...
Service point
Loading...
Alternative point

KRISONA 40 EEC

Dimensions scheme
A B C D E F G H ØI ØJ ØK ØL
240 224 113 95 49 275 42 18 151 146 153 216

KRISONA 40 EEC

Electrical scheme

KRISONA 40 EEC

Model
TB
Code
TB1670
Information
RIGID PVC PIPE FOR KRISONA EEC

Rigid PVC pipe (diameter 160 and length 700 mm) for wall mounting.

Model
PM
Code
PM316323
Information
METAL PANEL FOR KRISONA EEC

Metal panel “windbreak” for exterior in stainless steel sheet.

Model
REP
Code
REP260
Information
EXTERNAL RUBBER GRILL FOR KRISONA EEC

External rubber grille that can be installed from the inside wthi out the need for scaffolding.
 

Model
ACC
Code
ACC90
Information
CIRCULAR-RECTANGULAR ADAPTER FOR KRISONA EEC

90° Circular / Square Adapter for entry and exit through a window jamb.

Model
RINOX
Code
RINOXAAC
Information
RECTANGULAR STAINLESS STEEL GRILL FOR KRISONA EEC

Rectangular stainless steel grill for ACC window adapter kit 

Model
RINOXBACC
Code
RINOXBAAC
Information
RECTANGULAR GRID FOR KRISONA EEC

Rectangular grid in powder-coated stainless steel, white RAL 9003, for kit.

Model
STEMP
Code
STEMP3A
Information
SENSOR TO CONTROL THE AIR TEMPERATURE

Sensor to control the air temperature in the room: allows automatic start or speed change of the combined product when the temperature exceeds the preset value, selectable by external trimmer and adjustable in the range 10°C - 40°C. A timer allows the appliance to operate for a predetermined time, which can be set during installation from 3 to 20 minutes, after the temperature has dropped below the predetermined threshold.
Single-phase 220-240V / 50- 60 Hz power supply. Wall installation.
The color white.
Maximum allowable load: 3A.
Enclosure for wall installation with IP20 protection.

Model
SHR
Code
SHR3A
Information
SENSOR TO CONTROL THE RATE OF RELATIVE HUMIDITY

Sensor for controlling the rate of relative humidity (RH) in the air: allows automatic start or speed switching of the combined product when the percentage of RH exceeds 65%. If the humidity does not exceed the threshold, the associated appliance turns on automatically a few seconds after the light is turned on and continues to operate, after it is turned off, for a preset time, which can be set during installation from 3 to 20 minutes .
Single-phase power supply 220-240 V / 50-60 Hz. Wall installation. The color white.
Maximum admissible load: 3 A.
Enclosure for wall installation with IP20 protection.
Sensor para el control de la tasa de humedad relativa