HBX (ATEX)
Model
HBX 45 T6 (A0:6) Zone 1: FAN (Ex h IIB+H2 T4 Gb) + MOTOR (Ex eb IIC T4 Gb)
Code

HBX 45 T6 (A0:6) Zone 1: FAN (Ex h IIB+H2 T4 Gb) + MOTOR (Ex eb IIC T4 Gb)

AXIAL WALL ATEX FAN

MANUFACTURING FEATURES:
•Plate axial fan, circular reinforced frame.
•Motor-impeller assembly through modular system.
•Cast aluminium impeller.
• Corrosion-resistant powder coat polyester resin.
• Motor ATEX asíncrono normalizado. Certificado según zona indicada, . IP55 protection and class F insulation. Manufactured with standard voltages: 230/400V 60Hz in three phase motors up to 4kW and 400/690V 60Hz for higher powers.

APPLICATIONS:
Designed for wall or duct installation, they are suitable for:
• Fan for ventilations ATEX zones
• Smoke extraction (max 40ºC). 
• Working temperature: ambient from -20ºC to 40ºC

UNDER REQUEST:
• B Form impeller (air sense from impeller to motor). 100% reversible impeller.
___________________________

ORGANISM: L.O.M.
CERTIFICATE Nº:   LOM 17.755X-C

In compliance with the Directive 2014/34/UE

Fan

Max flow
4930 m³/h
HBX 45 T6 (A0:6) Zone 1: FAN (Ex h IIB+H2 T4 Gb) + MOTOR (Ex eb IIC T4 Gb)
Loading...
Design point
Loading...
Service point
Loading...
Alternative point

HBX 45 T6 (A0:6) Zone 1: FAN (Ex h IIB+H2 T4 Gb) + MOTOR (Ex eb IIC T4 Gb)

Dimensions scheme
C (Mot.T.100L) C (Mot.T.63) C (Mot.T.71) C (Mot.T.80) C (Mot.T.90L) C (Mot.T.90S) E O ØA ØB ØDint ØJ
418 328 328 347 387 362 165 8X45º 525 500 452 12

HBX 45 T6 (A0:6) Zone 1: FAN (Ex h IIB+H2 T4 Gb) + MOTOR (Ex eb IIC T4 Gb)

Electrical scheme

HBX 45 T6 (A0:6)

Model
RP0 450
Code
960001202
Information
Outlet protection guard for axial fans

MANUFACTURING FRATURES

• Protection grid on the outlet side to avoid the entry of objects and contact with the impeller.
• Made of welded metal wire.
• According to ROHS 2002/95/EC Directive.

UNDER REQUEST

• Stainless guard 304 or 316 with electro-polished finishing coat.

Model
PCP 45
Code
963240105G
Information
PLASTIC GRAVITY SHUTTER

Gravity shutter.
The shutter will open by air force and will close when the fan is stopped.
Made of ABS plastic.
UV rays protected.
Note: Maximum air speed 16 m/s

Model
AC 450
Code
960003213
Information
CONECTION FLANGE

MANUFACTURING FEATURES

• For axial (inlet and outlet) and centrifugal (inlet) fans.

UNDER REQUEST

• Versions in stainless 304 and stainless 316.

Model
BA-400 45
Code
960002055
Information
ANTI-VIBRATING FLANGE 400º/2H

MANUFACTURING FEATURES

• Flexible polyurethane coupling flange with fiberglass fabric to avoid possible vibrations to the installation.
• 160 mm width and supplied with 2 fixing clamps.
• Certified according to the European standard EN 12101-3 400ºC/2h. Fire classification: M0.

Model
MC HB 45
Code
960003154
Information
SQUARE MOUNTING FRAME FOR HB FANS

MANUFACTURING FEATURES

• Square support frame for HB fans.
• Made of steel and protected against corrosion with polyester resin powder.

Model
PC2 50
Code
PC25050
Information
ALUMINIUM GRAVITY SHUTTER

• Overpressure backward damper for facade made of extruded aluminum and standard natural aluminum finishing.
• It incorporates weatherstrip in the fins to achieve greater efficiency in the closure and noise damping.
• Maintains overpressure or depression inside a room with respect to the outside or other adjacent rooms.
• Drills incorporated in frame for wall or duct fixing with screws or rivets.
• Recommended maximum air passage speed 6m/s. maximum temperature of 80ºC.

Model
BAD 12 (Ø450)
Code
960003462
Information
CIRCULAR-CIRCULAR ANTI-VIBRATION FLANGE

MANUFACTURING FEATURES

• Circular-circular coupling flange through anti-vibration canvas.
• Fire resistance M0: from -50ºC to +200ºC in continuous and 400ºC/2h

Model
SFC (GENERIC)
Code
Information
FREQUENCY SPEED CONTROLLER

MANUFACTURING FEATURES

• Specially designed for speed frequency control in ventilation applications.
• Ultra compact, simple operation and wide range of functions.

*Dial panel incorporated. Optional EMC filter.

Certifications: CE/UL/CSA/EN/GOST/CCC.

Protection index IP20.

The selection of SFC frequency drive speed controller must be made based on the maximum intensity absorbed by the fan to be regulated. The powers (kW) and the intensity for constant load refer to the normal duty (150% overload for 60 seconds). The intensity for quadratic load admits an overload of 110% during 60s.

SFC 230: Entrance 230V I, exit 230V III
SFC 400: Entrance 400V III, exit 400V III

EMC filter incorporated for models from 47A (included)

*Lineal load rated current

**Quadratic load rated current

Model
INT ATEX (GENERIC)
Code
Information
ATEX SWITCH

Switch for ATEX environments. Suitable for zones 1-2 (gas) and 21-22 (dust), index protection IP65. Manufactured in aluminum alloy and RAL 7000 gray finishing coat. External screws in stainless steel. Control on the front. Tensions up to 690V. According to directive 2014/34 / UE (ATEX).

Model
RP1 (GENERIC)
Code
Information
INLET PROTECTION GUARD FOR AXIAL FANS

MANUFACTURING FRATURES

• Inlet protection guard to avoid the entry of objects and contact with the impeller.
• Made of welded metal wire.
• According to ROHS 2002/95/EC Directive.

UNDER REQUEST

• Stainless guard 304 or 316 with electro-polished finishing coat.

HBX 45 T6 (A0:6) Zone 1: FAN (Ex h IIB+H2 T4 Gb) + MOTOR (Ex eb IIC T4 Gb)