fan image
Model
BOX RLF 400 T4 1,1kW
Code
241390286

BOX RLF 400 T4 1,1kW

BACKWARD CURVED CENTRIFUGAL FAN IN SOUNDPROOF CABINET 400ºC/2H

MANUFACTURING FEATURES
• Box manufactured in galvanised steel sheet.
• Circular inlet flange.
• Backward impeller with self-cleaning system, direct coupling motor.
• Standard asynchronous squirrel-cage motor with IP-55 protection and Class H insulation type 400ºC/2h .
• Manufactured with standard voltages: 400-460V(Y) 60Hz in three phase motors up to 3kW and 400V(D) 60Hz for higher powers and 400V for 2 speed motors.
• Exchangeable pannels
• Open drive.

APPLICATIONS
Designed for inline installation, they are suitable for:
• Air renewal in buildings and industries.
• Maximum working temperature: 60ºC.
• Removing smoke in case of fire. The motor inside the hazardous area (400 ° C / 2 h)


Official homologation by the European laboratory APPLUS according to EN 12101-3:2015
Certification Nr: 0370-CPR-0582

Fan

Max flow
5860 m³/h
Weight
115 Kg

Motor

Power
1,1 kW
RPM Motor
1710
I max. 400 V
2,4
Weight
14 Kg
Efficiency
87.7 %
BOX RLF 400 T4 1,1kW
Loading...
Design point
Loading...
Service point
Loading...
Alternative point

BOX RLF 400 T4 1,1kW

Dimensions scheme
A B C D E G H J K L ØF
800 800 800 696 628,5 74 1002 952 628,5 558,5 398

BOX RLF 400 T4 1,1kW

Electrical scheme

BOX RLF 400 T4 1,1kW

Model
INT 25 3P A
Code
INT253PA
Information
SAFETY SWITCH

MANUFACTURING FEATURES

• Safety start-stop switches according to IEC 60947-1 and IEC 60947-3.
• IP65 and always equipped an auxiliary contact.
• Useful for switching off the current before handling the fan.

*Máx. thermal current air (A)

Model
SFC 400 III 3,6A *
Code
SFC400III4
Information
FREQUENCY SPEED CONTROLLER

MANUFACTURING FEATURES

• Specially designed for speed frequency control in ventilation applications.
• Ultra compact, simple operation and wide range of functions.

*Dial panel incorporated. Optional EMC filter.

Certifications: CE/UL/CSA/EN/GOST/CCC.

Protection index IP20.

The selection of SFC frequency drive speed controller must be made based on the maximum intensity absorbed by the fan to be regulated. The powers (kW) and the intensity for constant load refer to the normal duty (150% overload for 60 seconds). The intensity for quadratic load admits an overload of 110% during 60s.

SFC 230: Entrance 230V I, exit 230V III
SFC 400: Entrance 400V III, exit 400V III

EMC filter incorporated for models from 47A (included)

*Lineal load rated current

**Quadratic load rated current

BOX RLF 400 T4 1,1kW