MBP
Model
MBP 25 T2 0,37kW
Code
502202515

MBP 25 T2 0,37kW

MEDIUM PRESSURE WITH BACKWARD IMPELLER AND PLASTIC CONSTRUCTION 

MANUFACTURING FEATURES:

• PE plastic housing.
• Backward impeller with self-cleaning system in PP plastic.
• Motor support made of rolled steel sheet with polyester powder finishing coat.
• Stainless steel nuts and bolts.
• Standard asynchronous squirrel-cage motor, IP-55, class F insulation. Standard voltages 230/400V 50Hz

• Available positions (to be indicated in case of order): LG270, LG0, LG45, LG90, LG135, LG180, LG225, LG315, RD0, RD45, RD90, RD135, RD180, RD225, RD270, RD315.
• The indicated codes correspond to the model in position LG270

APPLICATIONS:

Designed for inline installation, they are suitable for:
• Corrosive air transport.
• Chemical and petrochemical industry.
• Laboratories and gas cabinets.

• Maximum temperature of transported air: If it is clean air 70ºC, other depends on the gas (see table in documentation)

UNDER REQUEST:

• Single phase motors (up to 1,1Kw).
• 60Hz fans and special voltages fans.
• 2 speed motors.
• Stainless steel motor support.
• Casing made of PP.

Fan

Max flow
2110 m³/h
Weight
13 Kg

Motor

Power
0.37 kW
RPM Motor
2730
I max. 230 V
1,7
I max. 400 V
0,97
Size
71
Efficiency
70 %
FP
0.79
MBP 25 T2 0,37kW
Loading...
Design point
Loading...
Service point
Loading...
Alternative point

MBP 25 T2 0,37kW

Dimensions scheme
A B C E F G H I L N P Q R S
173 228 35 200 185 170 55 310 190 220 255 100 140 290 11

MBP 25 T2 0,37kW

Electrical scheme

MBP 25 T2 0,37kW

Model
INT 25 3P A
Code
INT253PA
Information
SAFETY SWITCH

MANUFACTURING FEATURES

• Safety start-stop switches according to IEC 60947-1 and IEC 60947-3.
• IP65 and always equipped an auxiliary contact.
• Useful for switching off the current before handling the fan.

*Máx. thermal current air (A)

Model
BA-400 20
Code
960002066
Information
ANTI-VIBRATING FLANGE 400º/2H

MANUFACTURING FEATURES

• Flexible polyurethane coupling flange with fiberglass fabric to avoid possible vibrations to the installation.
• 160 mm width and supplied with 2 fixing clamps.
• Certified according to the European standard EN 12101-3 400ºC/2h. Fire classification: M0.

Model
JE 45
Code
A-300719201
Information
ANTI-VIBRATION JOINT

MANUFACTURING FEATURES

• Flexible joint to clinch the fan to the duct.
• Avoids transmission of vibrations for circular and rectangular connection.
• Dimensions: two metallic flanges of 45mm each one and a flexible flange of 60mm.
• The reel is 30,5m lenght.
• Maximum pressure: 20 mmca.
• Fire resistance M0 from -50ºC to +200ºC in continuous and 400ºC/2h.

Model
FJ Ø200
Code
FJ-200
Information
PVC FLEXIBLE JOINT

Flexible joint made of PVC

Model
DG Ø200
Code
DG200
Information
DIFUSOR GRID

Outlet with grid PVP/PP

Model
CSC Ø200
Code
CSC200
Information
CIRCULAR GRAVITY DAMPER

PVC/PP Gravity damper

Model
AD Ø200
Code
AD-200
Information
ADJUSTABLE DAMPER

Manual adjustable damper made of PVC/PP

Model
PD 1
Code
PD1
Information
DRAIN PLUG

Drain plug made of PP

Model
RPI Ø200
Code
RPI200
Information
STAINLESS STEEL PROTECTION GRID

Stainless steel protection grid

Model
WS 1
Code
WS1
Information
WALL SUPPORT

Wall support

(the code correspons to 2 units)

Model
AV 1
Code
AV-1
Information
ANTI-VITRATION BLOCK

Vibration absorbers KIT

Model
PC 25
Code
PC25
Information
CASING PROTECTION

PVC housing splinter protection

Model
PCM 1
Code
PCM1
Information
MOTOR PROTECTION

Motor protection cover

Model
SFC 230 I 2,5A *
Code
SFC230I003
Information
FREQUENCY SPEED CONTROLLER

MANUFACTURING FEATURES

• Specially designed for speed frequency control in ventilation applications.
• Ultra compact, simple operation and wide range of functions.

*Dial panel incorporated. Optional EMC filter.

Certifications: CE/UL/CSA/EN/GOST/CCC.

Protection index IP20.

The selection of SFC frequency drive speed controller must be made based on the maximum intensity absorbed by the fan to be regulated. The powers (kW) and the intensity for constant load refer to the normal duty (150% overload for 60 seconds). The intensity for quadratic load admits an overload of 110% during 60s.

SFC 230: Entrance 230V I, exit 230V III
SFC 400: Entrance 400V III, exit 400V III

EMC filter incorporated for models from 47A (included)

*Lineal load rated current

**Quadratic load rated current

Model
SFC 400 III 1,2A *
Code
SFC400III1
Information
FREQUENCY SPEED CONTROLLER

MANUFACTURING FEATURES

• Specially designed for speed frequency control in ventilation applications.
• Ultra compact, simple operation and wide range of functions.

*Dial panel incorporated. Optional EMC filter.

Certifications: CE/UL/CSA/EN/GOST/CCC.

Protection index IP20.

The selection of SFC frequency drive speed controller must be made based on the maximum intensity absorbed by the fan to be regulated. The powers (kW) and the intensity for constant load refer to the normal duty (150% overload for 60 seconds). The intensity for quadratic load admits an overload of 110% during 60s.

SFC 230: Entrance 230V I, exit 230V III
SFC 400: Entrance 400V III, exit 400V III

EMC filter incorporated for models from 47A (included)

*Lineal load rated current

**Quadratic load rated current

Model
AVR (GENERIC)
Code
Information
ANTI-VIBRATION RUBBER BLOCK

MANUFACTURING FEATURES

• Support of great radial and axial elasticity.
• These low-profile, compact and elastic supports control the three directions of movement with large deformations in the rubber.
• It consists of two parallel armour adhered to the bell-shaped rubber and by a base with handles.
• These supports with handles have a threaded hole in their upper frame and are easy to install and fix.
• The steel protection washer allows it to withstand overloads by increasing its rigidity and protects the rubber from dripping hydrocarbons.
• Elastomer type NR or high quality elastomer. Working temperatures between -40ºC and + 70º C.
• Taking into account the tolerances of hardness in the elastomers, the mechanical characteristics of these series may differ.
• Range of 6 sizes and 3 different hardnesses (45-60-75) to fit a load range between 2 Kg and 1300 Kg.
      1. Soft: hardness A 45
      2. Average: hardness B 60
      3. Hard: hardness C 75

APPLICATIONS

• Very appropriate in the elastic suspensions of machines that present vibrations of horizontal components.

Model
AVS (GENERIC)
Code
Information
ANTI-VIBRATION SPRING BLOCK

MANUFACTURING FEATURES

• Metal insulators designed to work with compression with 85% insulation according to the following arrows (travel in mm) and rpm:

Arrow (mm.)          r.p.m.
    20 mm          >600 r.p.m.
    30 mm          >500 r.p.m.

• Made of high quality elastic steel, with rectangular base and rubber mat to improve the grip. It treats of a resistant product and easy assembly, that avoids all type of vibrations of the fans to the structure of the premises.
• Operating temperature from -45 ° C to + 120 ° C.

APPLICATION

• To install under machines with rotating components, ventilation groups, fans, ventilation boxes, etc.

MBP 25 T2 0,37kW

Spare parts scheme
Code Family Name Qty
2 T02202515 TURBINE MBP 25 T2 0,37kW LG x1