CENTRIFUGAL IN SOUNDPROOF CABINET (DOUBLE)
MANUFACTURING FEATURES
• Impellers made of reinforced polyamide with fiber glass up to size 12/12 (33/33). Size 15/15 made of galvanized steel sheet.
• BD range fans assembled in soundproof cabinets with thermo-acoustic insulation, Bs1d0 fire class on the supply panel.
• Fan assembled on antivibration mountings.
• Connection gland included.
• Equipped with inlet deflector wing, minimizing the turbulence and optimizing efficiency.
• Closed motors specially designed by Casals. Extruded aluminium motor housing. Terminal box on the motor IP 65 protection and motor with IP54 protection and Class F insulation. Standard voltages 230V 50Hz for single phase and 230/400V 50Hz for three phase motors.
• Fans can run separately or simultaneously.
• Fans can run separately or simultaneously.
APPLICATIONS
Designed for inline installation, indoor or outdoor assembly, they are suitable for:
• Air renewal in buildings and industries.
• Industrial and professional kitchen hood. Use in supply or extraction with prior fat filtering.
• Maximum working temperature: 50ºC.
UNDER REQUEST
• 3 speed fans.
• LG0 position.
• Impeller made of galvanized sheet.
• Aluminium box up to size 12/12.
* All data are referred to a single working fan. If both fans are working at the same time, data should be twice (x2) except for weight.
A | B | C | D | E | F | H | I | J | K | L | M | N |
---|---|---|---|---|---|---|---|---|---|---|---|---|
1220 | 651 | 651 | 409 | 351 | 84 | 216 | 940 | 423 | 104 | 123 | 23 | 17 |
MANUFACTURING FEATURES
• Specially designed for sinus wave speed control. Only available for single phase fans.
• Terminal wiring.
• Minimum speed adjustable and potentiometer speed control.
• Sealed box IP-54 box. Light switch pilot.
• EMC filter according to the En55014 Standard.
MANUFACTURING FEATURES
• Safety start-stop switches according to IEC 60947-1 and IEC 60947-3.
• IP65 and always equipped an auxiliary contact.
• Useful for switching off the current before handling the fan.
*Máx. thermal current air (A)
MANUFACTURING FRATURES
• Frame made of galvanised sheet and shutters made of aluminium.
• To be fitted on centrifugal fans likeBVFC F400, BOX BD and BOX BV.
• Certified 400ºC/2h.
MANUFACTURING FEATURES
• Outdoor flange with bird guard.
• Made of galvanized Steel.
• VIS OUT = Outlet
• VIS IN = Inlet
WORKING FEATURES
• Electronic system designed and developed for automatic control of Twin-fans, like TWIN BOX BD and TWIN BOX BV.
• The REG TWIN control can be fitted within the Twin-fan housing or at any desired location of operation within the same building. The MODBUS communication protocol is integrated in the REG TWIN control.
• When REG TWIN is set to operate in AUTO mode, each fan will be running for a preset period of time interval (12 hours). In case of failure of any of the fan, REG TWIN automatically starts the Stand-By fan, simultaneously gives signal to the user about the faulty fan.
• An other function of REG TWIN is BOTH FANS RUNNING mode, to run both fans consequently to supply twice the normal air volume.
• Only suitable for single phase and electric motors (EEC).
CHARACTERISTICS
• Power supply: from 80 to 250 V. a.c. or d.c.
• Relay contacts current: 3 A 250 V. a.c. (For external intensities and three-phase motors an external contactor is necessary)
• Working temperature: from 0°C to 50°C.
• Storage temperature: from -25°C to 85°C.
• Relative humidity: max. 95% without condensation
• Dimensions: 104 x 93 x 25 mm.
CONNECTION OPTIONS
• Inside the unit (not connected).
• Attached outside the unit (the IP must be taken into account).
• Remote.
APPLICATIONS
This kind of control can be used to commutate a couple of motors to work in auto change over mode or simultaneously.
In case of TWIN BOX BD, a common application is in high temperatures environments (in the desert for example) where fans run in change over mode to avoid fan overheating problems.