CENTRIFUGAL FAN, FOR CLEAN OR SLIGHTLY DUSTY AIR AND BELT TRANSMISION
MANUFACTURING FEATURES
• Medium pressure centrifugal belt driven fan.
• Reinforced housing made of carbon laminated steel, protected against corrosion by powder coating polyester resin RAL 5010. Finish C3.
• Casing fully latched and adjustable.
• Self-cleaning turbine and reinforced impeller with high-performance backward (reaction) blades made of carbon laminated steel dynamically balanced to minimize noise and vibrations. Black painted RAL 9005
• Squirrel cage standardized asynchronous IEC motor with IP-55 protection and class F electrical insulation. Standard voltages 230/400V 50Hz for three-phase motors up to 4kW and 400/690V 50Hz for higher powers. IE4 motors for 75kW power or higher.
• Motorized fan with base frame (configuration 12). Full equipped fans including: motor, pulleys, belts, belts guard and shaft guard.
• Models of size 500 and above are supplied with a front support foot, for the other models the front support foot is optional.
• Maximum working temperature: carried air: 200ºC, ambient: 60ºC.
• Available positions (to be indicated in case of order): LG270, LG0, LG45, LG90, LG135, LG180, LG225, LG315, RD0, RD45, RD90, RD135, RD180, RD225, RD270, RD315.
• The indicated codes correspond to the model in position LG270
APPLICATIONS
Designed to be installed in duct for air extraction or supply in:
Paint booths
Collection of dust
Food industry dryers
Food processing
Incineration
Odor control in industry
Indoor / outdoor pollution control
Big buildings
Malls
Factories / Industrial buildings
Warehouses
Extraction of smoke
Boilers and ovens
Manufacture and treatment of chemical products.
Tunnels, underground stations.
ON DEMAND
· Fans for special voltages.
· 2 speed motor.
· C4 or C5 coating painting
· Hot dip galvanized
· Inox 304 (normal or electropolished finish)
· Inox 316 (normal or electropolished finish)
· Cooling wheel
· Anticaloric paint
· Fully welded housing (waterproof)
· Inspection door to facilitate maintenance and cleaning
· Drain plug.
· Airtight axle
· Non-sparking air passage and standard motor
· Other brands of motors.
A | B | C (T. mot< 200) | C (T. mot≥ 200) | C1 (T. mot< 200) | C1 (T. mot≥ 200) | C2 (T. mot< 200) | C2 (T. mot≥ 200) | D | D1 | D2 | D3 | DEC MIN/MAX (T. mot 132) | DEC MIN/MAX (T. mot 160) | DEC MIN/MAX (T. mot 180) | DEC MIN/MAX (T. mot 200) | DEC MIN/MAX (T. mot 225) | DEC MIN/MAX (T. mot 250) | E | F | G | H | I | J | K | L | M | N | N1 | N2 | O | ØU | P | Q (T. mot 100-112-132) | Q (T. mot 160-180) | Q (T. mot 200-225-250) | R | R1 | R2 | R3 | R4 | S | T | TM (T.mot. 132) | TM (T.mot. 160) | TM (T.mot. 180) | TM (T.mot. 200) | TM (T.mot. 225) | TM (T.mot. 250) | V | W | W1 | W2 | W3 | W4 | X | Y (T. mot 160-180) | Z | z1 (nº holes) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1720.6 | 2165 | 2035.7 | 2500.7 | 1825 | 1672.5 | 1735.5 | 2200.5 | 1641.7 | 20 | 20 | 11.5 | 1360/1500 | 1264/1430 | 1234/1430 | 1433/1731 | 1418/1701 | 1367/1667 | 214 | 676 | 103.75 | 642 | 1256 | 105 | 175 | 914.6 | 256.5 | 713 | 633 | 683 | 806 | 1093 | 160 | 51 | 72.9 | 79.9 | 1080 | 1000 | 1050 | 293 | 294 | 210.7 | 1201 | 132 | 160 | 180 | 200 | 225 | 250 | 40 | 739.6 | 627.4 | 55.8 | 749.3 | 600 | 49.5 | 785 | 835 | 16 |
MANUFACTURING FEATURES
• Flexible joint to clinch the fan to the duct.
• Avoids transmission of vibrations for circular and rectangular connection.
• Dimensions: two metallic flanges of 45mm each one and a flexible flange of 60mm.
• The reel is 30,5m lenght.
• Maximum pressure: 20 mmca.
• Fire resistance M0 from -50ºC to +200ºC in continuous and 400ºC/2h.
MANUFACTURING FEATURES
• Connection flange for rectangular outlet of STORM centrifugal fans making the connection to circular duct easier.
• Manufactured in galvanized steel.
UNDER REQUEST
• Versions in stainless 304 and stainless 316.
MANUFACTURING FEATURES
• Circular-circular coupling flange through anti-vibration canvas.
• Supplied with two O-shaped plates made of galvanized sheet metal and necessary screws.
MANUFACTURING FRATURES
• Inlet protection guard to avoid the entry of objects and contact with the impeller.
• Made of galvanised steel models 7,9, 10, 12 and 15. And the rest of models with polyester powder finishing coat.
MANUFACTURING FRATURES
• Protective grid for outlet installation in STORM medium pressure fans.
• Made of rolling steel sheet, protected against corrosion by powder coating of polyester resin.
*The Storm fan can be a NIMUS, NIMAX, PRESTUR, PREXTUR or IGNÉO
MANUFACTURING FEATURES
• Specially designed for speed frequency control in ventilation applications.
• Ultra compact, simple operation and wide range of functions.
*Dial panel incorporated. Optional EMC filter.
Certifications: CE/UL/CSA/EN/GOST/CCC.
Protection index IP20.
The selection of SFC frequency drive speed controller must be made based on the maximum intensity absorbed by the fan to be regulated. The powers (kW) and the intensity for constant load refer to the normal duty (150% overload for 60 seconds). The intensity for quadratic load admits an overload of 110% during 60s.
SFC 230: Entrance 230V I, exit 230V III
SFC 400: Entrance 400V III, exit 400V III
EMC filter incorporated for models from 47A (included)
*Lineal load rated current
**Quadratic load rated current
MANUFACTURING FEATURES
• Safety start-stop switches according to IEC 60947-1 and IEC 60947-3.
• IP65 and always equipped an auxiliary contact.
• Useful for switching off the current before handling the fan.
*Máx. thermal current air (A)
MANUFACTURING FEATURES
• Support of great radial and axial elasticity.
• These low-profile, compact and elastic supports control the three directions of movement with large deformations in the rubber.
• It consists of two parallel armour adhered to the bell-shaped rubber and by a base with handles.
• These supports with handles have a threaded hole in their upper frame and are easy to install and fix.
• The steel protection washer allows it to withstand overloads by increasing its rigidity and protects the rubber from dripping hydrocarbons.
• Elastomer type NR or high quality elastomer. Working temperatures between -40ºC and + 70º C.
• Taking into account the tolerances of hardness in the elastomers, the mechanical characteristics of these series may differ.
• Range of 6 sizes and 3 different hardnesses (45-60-75) to fit a load range between 2 Kg and 1300 Kg.
1. Soft: hardness A 45
2. Average: hardness B 60
3. Hard: hardness C 75
APPLICATIONS
• Very appropriate in the elastic suspensions of machines that present vibrations of horizontal components.
MANUFACTURING FEATURES
• Metal insulators designed to work with compression with 85% insulation according to the following arrows (travel in mm) and rpm:
Arrow (mm.) r.p.m.
20 mm >600 r.p.m.
30 mm >500 r.p.m.
• Made of high quality elastic steel, with rectangular base and rubber mat to improve the grip. It treats of a resistant product and easy assembly, that avoids all type of vibrations of the fans to the structure of the premises.
• Operating temperature from -45 ° C to + 120 ° C.
APPLICATION
• To install under machines with rotating components, ventilation groups, fans, ventilation boxes, etc.
Structure made of extruded aluminum profiles available in different dimensions according to the panel to be installed and the fan volume. The profiles joining is made of polyamide corners, which gives them great strength and the possibility of disassembling the structure into pieces.
Panels can be made of a single sheet with inner insulation of 10 mm thick polyethylene foam, or 2 sheets (sandwich panel) with thicknesses of 25 mm or 50 mm, depending on the required attenuation degree.
The sheets of each panel can be galvanized steel, galvanized steel with coloured plastic coating or stainless steel.
The lower part is finished off with a structure / plinth for transport and handling, made of galvanized sheet or upn-80/100 joist, depending on the cabin dimensions and weight.
The air inlets and outlets of the cabin have anti-vibration tarpaulins coupled to mounted fans. These fans rest on a floating base with acoustic dampers.
RRP to consult.