MEDIUM PRESSURE FAN WITH BACKWARD IMPELLER 400ºC/2H CERTIFIED INSIDE THE HAZARDOUS AREA
MANUFACTURING FEATURES
• Medium pressure centrifugal fan with direct coupling.
• Reinforced housing made of carbon laminated steel, protected against corrosion by powder coating polyester resin RAL 5010. Finish C3.
• Casing fully latched and adjustable.
• Self-cleaning turbine and reinforced impeller with high-performance backward (reaction) blades made of carbon laminated steel dynamically balanced to minimize noise and vibrations. Graffiti black RAL 9005.
• Motor with S1 service class for continuous operation and approved 400ºC / 2h for service class S2. IEC standardized asynchronous squirrel-cage motor with IP-55 protection and electrical insulation class H. Standard voltages 400V(Y) 50Hz in three phase motors up to 3kW and 400(D) 50Hz for higher powers.
• Motor with foot (B3) supported on motor support foot.
• Models of size 500 and above are supplied with a front support foot, for the other models the front support foot is optional.
• Inspection door to facilitate maintenance and cleaning.
• Available in the following orientations (to be indicated in case of order): LG0, LG45, LG90, LG135, LG180; LG225, LG270, LG315, RD0, RD45, RD90, RD135, RD180; RD225, RD270, RD315.
• Maximum working temperature in continuous: air transported: 130ºC (service S1) and 400ºC/2h (service S2), andmaximum environment temperature: 60ºC.
APPLICATIONS
Installation in conduit for the impulsion or aspiration of clean and dusty air in:
• Big buildings
• Malls
• Factories / Industrial buildings
• Warehouses
• Parking lots
• Catering / Hospitality
• Extraction of smoke
• Boilers and ovens
• Manufacture and treatment of chemical products.
• Tunnels, underground stations.
UNDER REQUEST
• Fans to work at 60Hz and special voltages.
• 2 speed motor.
• C4-C5
• Hot dip galvanized
• Fully welded housing (watertight)
• Drain plug
Official homologation by the European laboratory APPLUS according to EN 12101-3:2015
A1 | A2 | B1 | B2 | C1 | C2 | C3 | C4 | C5 | D | D1 | D2 | E | F | G | H | HC | I | J | K | L | M | N | N1 | N2 | O | P | Q | R | R1 | R2 | S | T | U | V | W | X | Y | Z |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
606 | 407.4 | 356.6 | 492.2 | 365 | 680.66 | 534.6 | 449.8 | 50.06 | 535 | 11.5 | 20 | 714.8 | 623.07 | 325 | 58.5 | 625.6 | 427.16 | 470.16 | 460.26 | 185 | 128 | 396 | 316 | 366 | 147 | 146 | 264.64 | 580 | 500 | 550 | 397 | 563 | 158.1 | 75.1 | 535.6 | 90 | M8 | 8x45º |
MANUFACTURING FEATURES
• Safety start-stop switches according to IEC 60947-1 and IEC 60947-3.
• IP65 and always equipped an auxiliary contact.
• Useful for switching off the current before handling the fan.
*Máx. thermal current air (A)
MANUFACTURING FRATURES
• Inlet protection guard to avoid the entry of objects and contact with the impeller.
• Made of galvanised steel models 7,9, 10, 12 and 15. And the rest of models with polyester powder finishing coat.
MANUFACTURING FEATURES
• For axial (inlet and outlet) and centrifugal (inlet) fans.
UNDER REQUEST
• Versions in stainless 304 and stainless 316.
MANUFACTURING FEATURES
• Flexible polyurethane coupling flange with fiberglass fabric to avoid possible vibrations to the installation.
• 160 mm width and supplied with 2 fixing clamps.
• Certified according to the European standard EN 12101-3 400ºC/2h. Fire classification: M0.
MANUFACTURING FEATURES
• Flexible joint to clinch the fan to the duct.
• Avoids transmission of vibrations for circular and rectangular connection.
• Dimensions: two metallic flanges of 45mm each one and a flexible flange of 60mm.
• The reel is 30,5m lenght.
• Maximum pressure: 20 mmca.
• Fire resistance M0 from -50ºC to +200ºC in continuous and 400ºC/2h.
MANUFACTURING FEATURES
• Connection flange for rectangular outlet of STORM centrifugal fans making the connection to circular duct easier.
• Manufactured in galvanized steel.
UNDER REQUEST
• Versions in stainless 304 and stainless 316.
MANUFACTURING FRATURES
• Protective grid for outlet installation in STORM medium pressure fans.
• Made of rolling steel sheet, protected against corrosion by powder coating of polyester resin.
*The Storm fan can be a NIMUS, NIMAX, PRESTUR, PREXTUR or IGNÉO
MANUFACTURING FEATURES
• Circular-circular coupling flange through anti-vibration canvas.
• Fire resistance M0 (from -50ºC to 200ºC in continious)
• Supplied with two O-shaped plates made of galvanized sheet metal and necessary screws.
MANUFACTURING FEATURES
• Rectangular-rectangular coupling flange through anti-vibration canvas.
• Fire resistance M0 (from -50ºC to 200ºC in continious)
• Supplied with four L-shaped plates made of galvanized sheet metal and necessary screws.
MANUFACTURING FEATURES
• Specially designed for speed frequency control in ventilation applications.
• Ultra compact, simple operation and wide range of functions.
*Dial panel incorporated. Optional EMC filter.
Certifications: CE/UL/CSA/EN/GOST/CCC.
Protection index IP20.
The selection of SFC frequency drive speed controller must be made based on the maximum intensity absorbed by the fan to be regulated. The powers (kW) and the intensity for constant load refer to the normal duty (150% overload for 60 seconds). The intensity for quadratic load admits an overload of 110% during 60s.
SFC 230: Entrance 230V I, exit 230V III
SFC 400: Entrance 400V III, exit 400V III
EMC filter incorporated for models from 47A (included)
*Lineal load rated current
**Quadratic load rated current
MANUFACTURING FEATURES
• Specially designed for speed frequency control in ventilation applications.
• Ultra compact, simple operation and wide range of functions.
*Dial panel incorporated. Optional EMC filter.
Certifications: CE/UL/CSA/EN/GOST/CCC.
Protection index IP20.
The selection of SFC frequency drive speed controller must be made based on the maximum intensity absorbed by the fan to be regulated. The powers (kW) and the intensity for constant load refer to the normal duty (150% overload for 60 seconds). The intensity for quadratic load admits an overload of 110% during 60s.
SFC 230: Entrance 230V I, exit 230V III
SFC 400: Entrance 400V III, exit 400V III
EMC filter incorporated for models from 47A (included)
*Lineal load rated current
**Quadratic load rated current
MANUFACTURING FEATURES
• Support of great radial and axial elasticity.
• These low-profile, compact and elastic supports control the three directions of movement with large deformations in the rubber.
• It consists of two parallel armour adhered to the bell-shaped rubber and by a base with handles.
• These supports with handles have a threaded hole in their upper frame and are easy to install and fix.
• The steel protection washer allows it to withstand overloads by increasing its rigidity and protects the rubber from dripping hydrocarbons.
• Elastomer type NR or high quality elastomer. Working temperatures between -40ºC and + 70º C.
• Taking into account the tolerances of hardness in the elastomers, the mechanical characteristics of these series may differ.
• Range of 6 sizes and 3 different hardnesses (45-60-75) to fit a load range between 2 Kg and 1300 Kg.
1. Soft: hardness A 45
2. Average: hardness B 60
3. Hard: hardness C 75
APPLICATIONS
• Very appropriate in the elastic suspensions of machines that present vibrations of horizontal components.
MANUFACTURING FEATURES
• Metal insulators designed to work with compression with 85% insulation according to the following arrows (travel in mm) and rpm:
Arrow (mm.) r.p.m.
20 mm >600 r.p.m.
30 mm >500 r.p.m.
• Made of high quality elastic steel, with rectangular base and rubber mat to improve the grip. It treats of a resistant product and easy assembly, that avoids all type of vibrations of the fans to the structure of the premises.
• Operating temperature from -45 ° C to + 120 ° C.
APPLICATION
• To install under machines with rotating components, ventilation groups, fans, ventilation boxes, etc.
Structure made of extruded aluminum profiles available in different dimensions according to the panel to be installed and the fan volume. The profiles joining is made of polyamide corners, which gives them great strength and the possibility of disassembling the structure into pieces.
Panels can be made of a single sheet with inner insulation of 10 mm thick polyethylene foam, or 2 sheets (sandwich panel) with thicknesses of 25 mm or 50 mm, depending on the required attenuation degree.
The sheets of each panel can be galvanized steel, galvanized steel with coloured plastic coating or stainless steel.
The lower part is finished off with a structure / plinth for transport and handling, made of galvanized sheet or upn-80/100 joist, depending on the cabin dimensions and weight.
The air inlets and outlets of the cabin have anti-vibration tarpaulins coupled to mounted fans. These fans rest on a floating base with acoustic dampers.
RRP to consult.
Frontal support for fans NIMUS NIMAX or IGNÉO
For mounting positions LG/RD0, LG/RD90 and LG/RD270
Models of size 500 and above are supplied with a front support foot, for the other models the front support foot is optional.
Made of steel with polyester resin powder coating.
Frontal support for fans NIMUS NIMAX or IGNÉO
For mounting all available positions
Models of size 500 and above are supplied with a front support foot, for the other models the front support foot is optional.
Made of steel with polyester resin powder coating.
Nº | Code | Family | Name | Qty |
---|---|---|---|---|
2 | R-BAD-N50 | INLET CONE | 500 | x1 |
3 | 721881156IE3 | MOTOR | 1,5KW 4P B3 400G | x1 |