CIKSTORM
Model
CIKSTORM 561 T6 1,5kW
Code
PF5616105LG

CIKSTORM 561 T6 1,5kW

REACTION CENTRIFUGAL FAN PLUG FOR INDUSTRIAL APPLICATIONS

MANUFACTURING FEATURES

• Centrifugal fan of medium pressure direct coupling type plug fan.
• Square frame made of carbon laminated steel, protected against corrosion by coating C3 finished paint.
• Self-cleaning turbine and reinforced impeller of high performance backward blades made of carbon laminated steel dynamically balanced to minimize noise and vibrations. C3 black paint.
• IE3 motor for continuous operation (S1). Standardized asynchronous squirrel cage motor with IP-55 protection and class F electrical isolation. Standard voltages 230/400V 50Hz for three-phase motors up to 4kW and 400/690V 50Hz for higher powers.
• Motor with flange (B5) and airtight shaft.
• Maximum continuous working temperature: ambient (motor): 60ºC.
• Suitable for transferring gases from -40ºC to 120ºC continuously.

 APPLICATIONS

Plug fan installation for gas recirculation in:
• Integrated in Machinery
• Paint booths
• Dryers of tobacco leaves, barley, ceramics, glass, wood
• Odor control in industry
• Indoor / outdoor pollution control
• Clean air drive and renewal
• Big buildings
• Malls
• Factories / Industrial buildings
• Warehouses
• Manufacture and treatment of chemical products.

UNDER REQUEST
• Fans for special voltages
• Refrigeration roll
• 2 speed motor
• C5 corrosion protection
• Anti-caloric paint
• Inox 304
• Inox 316
• Spark construction
• Other construction sizes
• Other motors according to customer requirements

Fan

Max flow
8400 m³/h
Weight
139 Kg

Motor

Power
1,5 kW
RPM Motor
940
I max. 230 V
6,45
I max. 400 V
3,71
Size
100L
Weight
28.5 Kg
Efficiency
82.5 %
FP
0.73
CIKSTORM 561 T6 1,5kW
Loading...
Design point
Loading...
Service point
Loading...
Alternative point

CIKSTORM 561 T6 1,5kW

Dimensions scheme
±B A C D E F G H K L
645.6 801 717 399 58 160 192 271.5 701 568

CIKSTORM 561 T6 1,5kW

Electrical scheme

CIKSTORM 561 T6 1,5kW

Model
INT 25 3P A
Code
INT253PA
Information
SAFETY SWITCH

MANUFACTURING FEATURES

• Safety start-stop switches according to IEC 60947-1 and IEC 60947-3.
• IP65 and always equipped an auxiliary contact.
• Useful for switching off the current before handling the fan.

*Máx. thermal current air (A)

Model
CLBI 56
Code
BAD-N56-A5
Information
INLET CONE FOR PLUG FANS IN CABINET

MANUFACTURING FEATURES

• Inlet cone for CLIBOS-TR, CLIBOS, CIKSTORM made of carbon steel and protected against corrosion by powder coating polyester resin RAL5010.

Model
CLBC 562 LG
Code
CLBC56-A5
Information
SCROLL FOR PLUG FANS

MANUFACTURING FEATURES

• Scroll for CLIBOS-TR, CLIBOS, CIKSTORM made of carbon steel and painted with anti-heat black paint

Model
SFC 230 I 7A *
Code
SFC230I007
Information
FREQUENCY SPEED CONTROLLER

MANUFACTURING FEATURES

• Specially designed for speed frequency control in ventilation applications.
• Ultra compact, simple operation and wide range of functions.

*Dial panel incorporated. Optional EMC filter.

Certifications: CE/UL/CSA/EN/GOST/CCC.

Protection index IP20.

The selection of SFC frequency drive speed controller must be made based on the maximum intensity absorbed by the fan to be regulated. The powers (kW) and the intensity for constant load refer to the normal duty (150% overload for 60 seconds). The intensity for quadratic load admits an overload of 110% during 60s.

SFC 230: Entrance 230V I, exit 230V III
SFC 400: Entrance 400V III, exit 400V III

EMC filter incorporated for models from 47A (included)

*Lineal load rated current

**Quadratic load rated current

Model
SFC 400 III 5A *
Code
SFC400III5
Information
FREQUENCY SPEED CONTROLLER

MANUFACTURING FEATURES

• Specially designed for speed frequency control in ventilation applications.
• Ultra compact, simple operation and wide range of functions.

*Dial panel incorporated. Optional EMC filter.

Certifications: CE/UL/CSA/EN/GOST/CCC.

Protection index IP20.

The selection of SFC frequency drive speed controller must be made based on the maximum intensity absorbed by the fan to be regulated. The powers (kW) and the intensity for constant load refer to the normal duty (150% overload for 60 seconds). The intensity for quadratic load admits an overload of 110% during 60s.

SFC 230: Entrance 230V I, exit 230V III
SFC 400: Entrance 400V III, exit 400V III

EMC filter incorporated for models from 47A (included)

*Lineal load rated current

**Quadratic load rated current