fan image
Model
REINTDECK WARRIOR 1800 EC
Code
REINT1800ECW

REINTDECK WARRIOR 1800 EC

CENTRALIZED, INTEGRABLE AND COMBINABLE FALSE CEILING PURIFIERS

MAIN FUNCTION
• REINTDECK WARRIOR by Casals air purifiers convert any indoor space into an environment free of contaminating particles and thus leave a much healthier air.
• It is designed to reduce the viral load of the rooms given the constant air renewals that it carries out.
MANUFACTURING FEATURES
CHASIS:
• Soundproof 30mm extruded aluminum profile, nylon corners and pre lacquered steel sandwich panels, RAL 9006, class M0, with 25mm internal rockwool insulation class A1 (non combustible) and 90Kg/m3 density.  Panels come with quick release fastening system for easy assembly and disassembly whenever required, whether for cleaning, maintenance or panel repositioning.
• Filters are located in the perforated side panels, with handles and fastening system.  This ease of access optimizes maintenance and filter replacement procedures.  Filter replacement and manipulation of the REINTDECK is recommended with the appropriate PPE’s.
FAN:
• Equipped with high efficiency single inlet - backward impeller with self-cleaning system, made of polyamide, statically and dynamically balanced at the factory.
FILTERS
• Triple filtering stage at each panel, comprised of 5x ISO Coarse≥60% (G4) + 5 ISO ePM1≥50% (F7) + 5  HEPA H14. The ISO Coarse≥60% pre-filters increase the life of the absolute filters HEPA H14.
MOTORS:
• Low consumption EC (electronically commutated) Technology exterior rotor motor.  IP-44 protection and class B insulation.  Standard voltage 230V 50Hz/60Hz. EEC PM MOTORS
• All REINTDECK and REINTDECK EASY air purifiers are equipped with a master control panel located on one side of the structure.
APPLICATIONS
Designed for all kind of indoor spaces such as:
• Supermarkets
• Pavilions
• Gyms
• Restaurants
• Health sector
• Offices
• Hotels
• Homes
• Colleges and universities
In short, for any public space where high-quality air purification is required since REINTDECK purifiers are equipped with high-efficiency HEPA H-14 filters. Designed to be installed in indoor spaces in false ceilings, or by simple hanging, which makes them the best solution for:
• Ventilation of workstations.
• The health sector (waiting rooms, corridors, rooms, field hospitals, common areas, clinics, pharmacies, etc.).
• The tertiary and industrial sector (gyms, pavilions, supermarkets, offices, hotels, universities, schools, public institutions, warehouses, living rooms in restaurants, shops, etc.).

Fan

Max flow
1800 m³/h
Weight
96 Kg

Motor

Power
0,36 kW
RPM Motor
2350
I max. 230 V
1,7
Weight
5 Kg
REINTDECK WARRIOR 1800 EC
Loading...
Design point
Loading...
Service point
Loading...
Alternative point

REINTDECK WARRIOR 1800 EC

Dimensions scheme

REINTDECK WARRIOR 1800 EC

Electrical scheme

REINTDECK WARRIOR 1800 EC

Model
FILT H14 (305x610x66-69) ABSOLUTO FLUJO LAMINAR
Code
FILTH14006
Information
ABSOLUTE FILTER FOR TERMINAL FILTRATION

• Terminal filtration for clean room applications.
• Large air flow with very low pressure drop.
• Mini-folded glass microfibre paper stocking.
• Extruded anodized aluminium frame.
• Sealant: polyurethane.
• Separator: continuous thermoplastic cords.
• Gasket: half round monoblock polyurethane.
• Grilles: Epoxy painted (both sides).
• Maximum temperature in continuous service 80ºC.
• Relative humidity 70-80%.
• Approved for contact with food according to CE 1935/2004.
• Certified against microbial growth (ISO 846-VD 6022).

Model
FILT ISO Coarse≥60% (592x287x20-24) PREFILTRO MARCO FIBERPLAST
Code
FILTG04004
Information
FILTER CELLS WITH FIBERPLAST FRAME

Filter cells for rough primary filtration for air treatment units

High filtration area, light filter, rigid and easy to compact. 100% Incinerable and water repellent

Media: synthetic thermo pleated
FiberPlast frame

Maximum temperature in continuos service: 70ºC
Humidity 100%HC

Tested for food contact according to CE 1935/2004

Model
FILT H14 (610x610x68) ABSOLUTO FLUJO LAMINAR
Code
FILTH14002
Information
ABSOLUTE FILTER FOR TERMINAL FILTRATION

• Terminal filtration for clean room applications.
• Large air flow with very low pressure drop.
• Mini-folded glass microfibre paper stocking.
• Extruded anodized aluminium frame.
• Sealant: polyurethane.
• Separator: continuous thermoplastic cords.
• Gasket: half round monoblock polyurethane.
• Grilles: Epoxy painted (both sides).
• Maximum temperature in continuous service 80ºC.
• Relative humidity 70-80%.
• Approved for contact with food according to CE 1935/2004.
• Certified against microbial growth (ISO 846-VD 6022).

Model
FILT ISO Coarse≥60% (592x592x20) PREFILTRO MARCO FIBERPLAST
Code
FILTG04002
Information
FILTER CELLS WITH FIBERPLAST FRAME

Filter cells for rough primary filtration for air treatment units

High filtration area, light filter, rigid and easy to compact. 100% Incinerable and water repellent

Media: synthetic thermo pleated
FiberPlast frame

Maximum temperature in continuos service: 70ºC
Humidity 100%HC

Tested for food contact according to CE 1935/2004

Model
FILT ePM1≥50% (610x305x48) ALTA EFIC. PANEL MINIPLEGADO
Code
FILTF07010
Information
HIGH EFFICIENCY, RIGID AND COMPACT FILTER

Filtration for air treatment units equipped with a pre-filter upstream, and air-conditioning units.

High filtration area, high efficiency, compact and economic filter.

Media: Mini pleat fiberglass paper
Frame: Galvanized steel

Maximum T° in continuous service: 100°C
Humidity: 100% RH

Tested for food contact according to CE 1935/2004
Certified for microbial development (ISO 846-VD 6022)

Model
FILT ePM1≥50% (610x610x48) ALTA EFIC. PANEL MINIPLEGADO
Code
FILTF07011
Information
HIGH EFFICIENCY, RIGID AND COMPACT FILTER

Filtration for air treatment units equipped with a pre-filter upstream, and air-conditioning units.

High filtration area, high efficiency, compact and economic filter.

Media: Mini pleat fiberglass paper
Frame: Galvanized steel

Maximum T° in continuous service: 100°C
Humidity: 100% RH

Tested for food contact according to CE 1935/2004
Certified for microbial development (ISO 846-VD 6022)