PRESTUR ATEX
Model
PRESTUR 561 T4 2,2kW ATEX Zone 2: FAN (Ex h IIB T3 Gc) + MOTOR (Ex ec IIC T3 Gc)
Code
PS5614100XN

PRESTUR 561 T4 2,2kW ATEX Zone 2: FAN (Ex h IIB T3 Gc) + MOTOR (Ex ec IIC T3 Gc)

MEDIUM PRESSURE FAN, BACKWARD IMPELER, DIRECT DRIVEN WITH FLANGED MOTOR ATEX

MANUFACTURING FEATURES:

• Medium pressure centrifugal fan with direct coupling.
• Reinforced housing made of carbon laminated steel, protected against corrosion by powder coating polyester resin RAL 5010. Finish C3.
• Self-cleaning turbine and reinforced impeller with high-performance backward (reaction) blades made of carbon laminated steel dynamically balanced to minimize noise and vibrations. Black painting RAL 9005
• ATEX standard asynchronous motor.  ATEX certified according to the zone. Class F insulation. Manufactured with standard voltages: 230/400V 50Hz in three phase motors up to 4kW and 400/690V 50Hz for higher powers.
• Motor with flange (B5), airtight axle
• Double suction flange
• Working temperature: ambient from -20ºC to 40ºC, transported air according to the ATEX clasification.

• Available positions (to be indicated in case of order): LG and RD
• The indicated codes correspond to the model in position LG

APPLICATIONS

• Ventilation in indoor environments classified as ATEX. Suitable for moving clean or dusty air. Designed to be fixed in the double suction flange, with the motor in vertical position.

  •      Paint booths
  •      Collection of dust
  •      Food industry dryers
  •      Food processing
  •      Incineration
  •      Odor control in industry
  •      Indoor / outdoor pollution control
  •      Big buildings
  •      Malls
  •      Factories / Industrial buildings
  •      Warehouses
  •      Extraction of smoke
  •      Boilers and ovens
  •      Manufacture and treatment of chemical products.
  •      Tunnels, underground stations.

ON DEMAND

· Fans for 60Hz and special voltages.
· Inox 304 (normal or electropolished finish)
· Inox 316 (normal or electropolished finish)
· Inspection door to facilitate maintenance and cleaning.

Fan

Max flow
13250 m³/h
Weight
174 Kg

Motor

Power
2,2 kW
RPM Motor
1440
I max. 400 V
5,8
Size
100L
Weight
20 Kg
Efficiency
80 %
FP
0.77
PRESTUR 561 T4 2,2kW ATEX Zone 2: FAN (Ex h IIB T3 Gc) + MOTOR (Ex ec IIC T3 Gc)
Loading...
Design point
Loading...
Service point
Loading...
Alternative point

PRESTUR 561 T4 2,2kW ATEX Zone 2: FAN (Ex h IIB T3 Gc) + MOTOR (Ex ec IIC T3 Gc)

Dimensions scheme
A1 A2 A3 B1 B2 B3 D E F G J K L M N N1 nºholes O P R R1
394 548.5 358.5 11,25º 674 453.5 643.5 354 650 608 862.6 314.6 363 185 147 434 354 16x22,5º 165 170 640 560

PRESTUR 561 T4 2,2kW ATEX Zone 2: FAN (Ex h IIB T3 Gc) + MOTOR (Ex ec IIC T3 Gc)

Electrical scheme

PRESTUR 561 T4 2,2kW ATEX

Model
RA 56/18
Code
A-243561901
Information
INLET PROTECTION GUARD FOR CENTRIFUGAL FANS

MANUFACTURING FRATURES

• Inlet protection guard to avoid the entry of objects and contact with the impeller.
• Made of galvanised steel models 7,9, 10, 12 and 15. And the rest of models with polyester powder finishing coat.

Model
AC 560
Code
960003215
Information
CONECTION FLANGE

MANUFACTURING FEATURES

• For axial (inlet and outlet) and centrifugal (inlet) fans.

UNDER REQUEST

• Versions in stainless 304 and stainless 316.

Model
BA-400 56
Code
960002056
Information
ANTI-VIBRATING FLANGE 400º/2H

MANUFACTURING FEATURES

• Flexible polyurethane coupling flange with fiberglass fabric to avoid possible vibrations to the installation.
• 160 mm width and supplied with 2 fixing clamps.
• Certified according to the European standard EN 12101-3 400ºC/2h. Fire classification: M0.

Model
JE 45
Code
A-300719201
Information
ANTI-VIBRATION JOINT

MANUFACTURING FEATURES

• Flexible joint to clinch the fan to the duct.
• Avoids transmission of vibrations for circular and rectangular connection.
• Dimensions: two metallic flanges of 45mm each one and a flexible flange of 60mm.
• The reel is 30,5m lenght.
• Maximum pressure: 20 mmca.
• Fire resistance M0 from -50ºC to +200ºC in continuous and 400ºC/2h.

Model
EIS 560x354-560
Code
EIS-5635456
Information
OUTLET FLANGE FOR STORM MODELS

MANUFACTURING FEATURES

• Connection flange for rectangular outlet of STORM centrifugal fans making the connection to circular duct easier.
• Manufactured in galvanized steel.

UNDER REQUEST

• Versions in stainless 304 and stainless 316.

Model
RIS 560x354
Code
RIS-56354E2
Information
OUTLET PROTECTION GUARD FOR STORM FANS

MANUFACTURING FRATURES

• Protective grid for outlet installation in STORM medium pressure fans.
• Made of rolling steel sheet, protected against corrosion by powder coating of polyester resin.

*The Storm fan can be a NIMUS, NIMAX, PRESTUR, PREXTUR or IGNÉO

Model
BADS ATEX 560
Code
BADS-5656X0
Information
CIRCULAR-CIRCULAR COUPLING FLANGE ATEX FOR STORM

MANUFACTURING FEATURES

• Circular-circular coupling flange through anti-vibration canvas ATEX.
• Supplied with two O-shaped plates made of galvanized sheet metal and necessary screws.

Model
BIDS ATEX 354x560-200
Code
BIDS-56354X0
Information
RECTANGULAR-RECTANGULAR COUPLING FLANGE ATEX FOR STORM

MANUFACTURING FEATURES

• Rectangular-rectangular coupling flange through anti-vibration canvas ATEX.
• Supplied with four L-shaped plates made of galvanized sheet metal and necessary screws.

Model
INT 16 ATEX
Code
510200016X
Information
ATEX SWITCH

Switch for ATEX environments. Suitable for zones 1-2 (gas) and 21-22 (dust), index protection IP65. Manufactured in aluminum alloy and RAL 7000 gray finishing coat. External screws in stainless steel. Control on the front. Tensions up to 690V. According to directive 2014/34 / UE (ATEX).

Model
SFC 400 III 8A *
Code
SFC400III8
Information
FREQUENCY SPEED CONTROLLER

MANUFACTURING FEATURES

• Specially designed for speed frequency control in ventilation applications.
• Ultra compact, simple operation and wide range of functions.

*Dial panel incorporated. Optional EMC filter.

Certifications: CE/UL/CSA/EN/GOST/CCC.

Protection index IP20.

The selection of SFC frequency drive speed controller must be made based on the maximum intensity absorbed by the fan to be regulated. The powers (kW) and the intensity for constant load refer to the normal duty (150% overload for 60 seconds). The intensity for quadratic load admits an overload of 110% during 60s.

SFC 230: Entrance 230V I, exit 230V III
SFC 400: Entrance 400V III, exit 400V III

EMC filter incorporated for models from 47A (included)

*Lineal load rated current

**Quadratic load rated current

Model
AVR (GENERIC)
Code
Information
ANTI-VIBRATION RUBBER BLOCK

MANUFACTURING FEATURES

• Support of great radial and axial elasticity.
• These low-profile, compact and elastic supports control the three directions of movement with large deformations in the rubber.
• It consists of two parallel armour adhered to the bell-shaped rubber and by a base with handles.
• These supports with handles have a threaded hole in their upper frame and are easy to install and fix.
• The steel protection washer allows it to withstand overloads by increasing its rigidity and protects the rubber from dripping hydrocarbons.
• Elastomer type NR or high quality elastomer. Working temperatures between -40ºC and + 70º C.
• Taking into account the tolerances of hardness in the elastomers, the mechanical characteristics of these series may differ.
• Range of 6 sizes and 3 different hardnesses (45-60-75) to fit a load range between 2 Kg and 1300 Kg.
      1. Soft: hardness A 45
      2. Average: hardness B 60
      3. Hard: hardness C 75

APPLICATIONS

• Very appropriate in the elastic suspensions of machines that present vibrations of horizontal components.

Model
AVS (GENERIC)
Code
Information
ANTI-VIBRATION SPRING BLOCK

MANUFACTURING FEATURES

• Metal insulators designed to work with compression with 85% insulation according to the following arrows (travel in mm) and rpm:

Arrow (mm.)          r.p.m.
    20 mm          >600 r.p.m.
    30 mm          >500 r.p.m.

• Made of high quality elastic steel, with rectangular base and rubber mat to improve the grip. It treats of a resistant product and easy assembly, that avoids all type of vibrations of the fans to the structure of the premises.
• Operating temperature from -45 ° C to + 120 ° C.

APPLICATION

• To install under machines with rotating components, ventilation groups, fans, ventilation boxes, etc.

Model
AB (GENERIC)
Code
Information
ACOUSTIC CABINS FOR CENTRIFUGAL FANS

Structure made of extruded aluminum profiles available in different dimensions according to the panel to be installed and the fan volume. The profiles joining is made of polyamide corners, which gives them great strength and the possibility of disassembling the structure into pieces.

Panels can be made of a single sheet with inner insulation of 10 mm thick polyethylene foam, or 2 sheets (sandwich panel) with thicknesses of 25 mm or 50 mm, depending on the required attenuation degree.

The sheets of each panel can be galvanized steel, galvanized steel with coloured plastic coating or stainless steel.

The lower part is finished off with a structure / plinth for transport and handling, made of galvanized sheet or upn-80/100 joist, depending on the cabin dimensions and weight.

The air inlets and outlets of the cabin have anti-vibration tarpaulins coupled to mounted fans. These fans rest on a floating base with acoustic dampers.

RRP to consult.

PRESTUR 561 T4 2,2kW ATEX Zone 2: FAN (Ex h IIB T3 Gc) + MOTOR (Ex ec IIC T3 Gc)