FAN DOUBLE INLET
MANUFACTURING FEATURES:
• Galvanised steel sheet housing.
• Polyamide impeller reinforced with fibreglass in models 7/7, 9/9, 10/10 and 12/12. The impeller of the rest of models are made of galvanised steel sheet.
• Double inlet forward curved impeller in all models.
• Supplied with mounting feet (included in price). Except 15/15 which is a cubic model.
•Exclusive system Casals fixing motor and turbine fan by flexible arms silent blocks to avoid any vibration. Arms in compliance with ROHS regulations 2002/95 / EC (Restriction of Hazardous Substances in electrical and electronic equipment)
•Closed motors specially designed Casals: extruded aluminum housing, all protected inside the terminal box on the motor IP 65 protection and motor with IP54 protection and Class F insulation standard voltages: 230V 50Hz in single phase and 230/400V 50Hz three-phase.
• Single phase motors with controllable voltage speed. Three phase motors controllable using a frecuency speed controller
APPLICATIONS:
Designed for assembly in equipment:
• Ventilation boxes and air handling units.
• Centrifugal heaters.
• Industrial and professional kitchen hoods. Use in supply or extraction with prior fat filtering.
• Maximum working temperature: 50ºC for single phase motors and 60ºC for three phase motors.
UNDER REQUEST
• Impeller made of galvanized steel sheet.
• MBI assembled
A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | X |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
473 | 522,8 | 210 | 210 | 210 | 210 | 628 | 501,5 | 585 | 531,5 | 271 | 98,5 | 66,5 | 404 | 10 | 20 | 279 | 315 |
MANUFACTURING FEATURES
• Safety start-stop switches according to IEC 60947-1 and IEC 60947-3.
• IP65 and always equipped an auxiliary contact.
• Useful for switching off the current before handling the fan.
*Máx. thermal current air (A)
MANUFACTURING FRATURES
• Galvanized protection grid on the outlet side to avoid the entry of objects and contact with the impeller.
MANUFACTURING FRATURES
• Inlet protection guard to avoid the entry of objects and contact with the impeller.
• Made of galvanised steel models 7,9, 10, 12 and 15. And the rest of models with polyester powder finishing coat.
MANUFACTURING FEATURES
• To be installed in the outlet of low pressure fans (BD, BV) and made the connection to the duct easier.
• Made of galvanized seel.
UNDER REQUEST
• Possible spot welding on fans outlet.
MANUFACTURING FEATURES
• Specially designed for speed frequency control in ventilation applications.
• Ultra compact, simple operation and wide range of functions.
*Dial panel incorporated. Optional EMC filter.
Certifications: CE/UL/CSA/EN/GOST/CCC.
Protection index IP20.
The selection of SFC frequency drive speed controller must be made based on the maximum intensity absorbed by the fan to be regulated. The powers (kW) and the intensity for constant load refer to the normal duty (150% overload for 60 seconds). The intensity for quadratic load admits an overload of 110% during 60s.
SFC 230: Entrance 230V I, exit 230V III
SFC 400: Entrance 400V III, exit 400V III
EMC filter incorporated for models from 47A (included)
*Lineal load rated current
**Quadratic load rated current
Nº | Code | Family | Name | Qty |
---|---|---|---|---|
2 | R-252379382 | TURBINE | BD 15/15 | x1 |
3 | 252379476 | MOTOR+SUPPORTS | BD39T6-3 M/C | x1 |
3 | 721081261 | MOTOR | BD T6 2,2kW 230/400V | x1 |