Sistemas SYSTEMS 961 CV092024 DAMPER2DUALSTAIRSHIELD Code Model Max. I. (A) Weight kg Conection diagram KPESSDI01D2 KIT PE DAMPER 2 DUAL STAIRSHIELD I 2,5A (0,4kW) in: 230Vac II, out: 230Vac III 2,5 20,50 1 KPESSDI03D2 KIT PE DAMPER 2 DUAL STAIRSHIELD I 4,2A (0,75kW) in: 230Vac II, out: 230Vac III 4,2 20,50 1 KPESSDI04D2 KIT PE DAMPER 2 DUAL STAIRSHIELD I 7A (1,5kW) in: 230Vac II, out: 230Vac III 7 20,50 1 KPESSDI05D2 KIT PE DAMPER 2 DUAL STAIRSHIELD I 10A (2,2kW) in: 230Vac II, out: 230Vac III 10 20,50 1 KPESSDIII01D2 KIT PE DAMPER 2 DUAL STAIRSHIELD III 2,2A (0,75kW) in: 400Vac III, out: 400Vac III 2,2 20,50 2 KPESSDIII02D2 KIT PE DAMPER 2 DUAL STAIRSHIELD III 3,6A (1,5kW) in: 400Vac III, out: 400Vac III 3,6 20,50 2 KPESSDIII03D2 KIT PE DAMPER 2 DUAL STAIRSHIELD III 5A (2,2kW) in: 400Vac III, out: 400Vac III 5 23,50 2 KPESSDIII04D2 KIT PE DAMPER 2 DUAL STAIRSHIELD III 8A (4kW) in: 400Vac III, out: 400Vac III 8 23,50 2 KPESSDIII05D2 KIT PE DAMPER 2 DUAL STAIRSHIELD III 12A (5,5kW) in: 400Vac III, out: 400Vac III 12 23,50 2 KPESSDIII06D2 KIT PE DAMPER 2 DUAL STAIRSHIELD III 16A (7,5kW) in: 400Vac III, out: 400Vac III 16 28,50 2 KPESSDIII07D2 KIT PE DAMPER 2 DUAL STAIRSHIELD III 23A (11,0kW) in: 400Vac III, out: 400Vac III 23 28,50 2 KPESSDIII08D2 KIT PE DAMPER 2 DUAL STAIRSHIELD III 29,5A (15,0kW) in: 400Vac III, out: 400Vac III 29,5 35,50 2 KPESSDIII09D2 KIT PE DAMPER 2 DUAL STAIRSHIELD III 41A (18,5kW) in: 400Vac III, out: 400Vac III 41 35,50 2 NOTE. The COMBATOR firefighter box is an accessory and is only supplied together with the KIT-PE STAIRSHIELD NOTA. El cuadro de bomberos COMBATOR es un accesorio y sólo se suministra junto al KIT-PE STAIRSHIELD COMBATOR DAMPER 2 DUAL StairShield Code Model Weight kg COMBSSDD2 COMBATOR DAMPER 2 DUAL STAIRSHIELD 1 DIMENSIONS / dimensiones Model A B C KIT PE DAMPER 2 DUAL STAIRSHIELD 500 500 210 Model A B C COMBATOR DAMPER 2 DUAL STAIRSHIELD 240 190 95 B A C B A C • Allows the control of two motorized regulation dampers and a fan for each damper that work separately. In the case of detecting smoke, the damper that detects it will close and stop the fan so that smoke does not enter. Meanwhile, the other fan will continue to pressurize as long as its damper does not detect a smoke signal. • Permite controlar dos compuertas de regulación motorizadas y un ventilador para cada compuerta que funcionan por separado. En el caso de detectarse humo, la compuerta que lo detecte se cerrará y hará que se pare el ventilador para que no entre el humo. Mientras tanto, el otro ventilador seguirá presurizando siempre y cuando su compuerta no detecte señal de humo. StairShield dual DAMPER 2
RkJQdWJsaXNoZXIy MTE4OTIxMQ==