Sistemas SYSTEMS 958 CV092024 DAMPER1DUALSTAIRSHIELD Code Model Max. I. (A) Weight kg Conection diagram KPESSDI01D1 KIT PE DAMPER 1 DUAL STAIRSHIELD I 2,5A (0,4kW) in: 230Vac II, out: 230Vac III 2,5 20,50 1 KPESSDI03D1 KIT PE DAMPER 1 DUAL STAIRSHIELD I 4,2A (0,75kW) in: 230Vac II, out: 230Vac III 4,2 20,50 1 KPESSDI04D1 KIT PE DAMPER 1 DUAL STAIRSHIELD I 7A (1,5kW) in: 230Vac II, out: 230Vac III 7 20,50 1 KPESSDI05D1 KIT PE DAMPER 1 DUAL STAIRSHIELD I 10A (2,2kW) in: 230Vac II, out: 230Vac III 10 20,50 1 KPESSDIII01D1 KIT PE DAMPER 1 DUAL STAIRSHIELD III 2,2A (0,75kW) in: 400Vac III, out: 400Vac III 2,2 20,50 2 KPESSDIII02D1 KIT PE DAMPER 1 DUAL STAIRSHIELD III 3,6A (1,5kW) in: 400Vac III, out: 400Vac III 3,6 20,50 2 KPESSDIII03D1 KIT PE DAMPER 1 DUAL STAIRSHIELD III 5A (2,2kW) in: 400Vac III, out: 400Vac III 5 23,50 2 KPESSDIII04D1 KIT PE DAMPER 1 DUAL STAIRSHIELD III 8A (4kW) in: 400Vac III, out: 400Vac III 8 23,50 2 KPESSDIII05D1 KIT PE DAMPER 1 DUAL STAIRSHIELD III 12A (5,5kW) in: 400Vac III, out: 400Vac III 12 23,50 2 KPESSDIII06D1 KIT PE DAMPER 1 DUAL STAIRSHIELD III 16A (7,5kW) in: 400Vac III, out: 400Vac III 16 28,50 2 KPESSDIII07D1 KIT PE DAMPER 1 DUAL STAIRSHIELD III 23A (11,0kW) in: 400Vac III, out: 400Vac III 23 28,50 2 KPESSDIII08D1 KIT PE DAMPER 1 DUAL STAIRSHIELD III 29,5A (15,0kW) in: 400Vac III, out: 400Vac III 29,5 35,50 2 KPESSDIII09D1 KIT PE DAMPER 1 DUAL STAIRSHIELD III 41A (18,5kW) in: 400Vac III, out: 400Vac III 41 35,50 2 NOTE. The COMBATOR firefighter box is an accessory and is only supplied together with the KIT-PE STAIRSHIELD NOTA. El cuadro de bomberos COMBATOR es un accesorio y sólo se suministra junto al KIT-PE STAIRSHIELD StairShield dual DAMPER 1 COMBATOR DAMPER 1 DUAL StairShield Code Model Weight kg COMBSSDD1 COMBATOR DAMPER 1 DUAL STAIRSHIELD 1 DIMENSIONS / dimensiones Model A B C KIT PE DAMPER 1 DUAL STAIRSHIELD 500 500 210 Model A B C COMBATOR DAMPER 1 DUAL STAIRSHIELD 240 190 95 B A C B A C • It allows to control a motorized regulation damper and two fans with alternative operation. If smoke is detected, the damper will close and the fan that was running will stop. If there is no smoke, but one of the fans fails, there will always be the other to continue pressurizing. • Permite controlar una compuerta de regulación motorizada y dos ventiladores con funcionamiento alternativo. En el caso de detectarse humo, la compuerta se cerrará y el ventilador que estaba funcionando se parará. Si no hubiera humo, pero uno de los ventiladores falla, siempre habrá el otro para seguir presurizando.
RkJQdWJsaXNoZXIy MTE4OTIxMQ==