Ventiladores ATEX ATEX FANS 745 CV092024 6 POLE / 6 POLOS 4 POLE / 4 POLOS 6 POLE / 6 POLOS Code Model R.P.M. Rated I (A) 230V Rated Power kW Air flow m3/h Sound dB (A) Weight Kg Connection diagram 279410103AXD CTH3-A 400 M6 0,37kW ATEX 890 2,9 0,37 3.550 47 21 1 Code Model R.P.M. Rated I (A) Rat. Power kW Air flow m3/h Sound dB (A) Weight Kg Connection diagram 230V 400V 279310106AXY CTH3-A 315 T4 0,25kW ATEX 1400 1,38 0,79 0,25 2.300 48 15 2 279350106AXY CTH3-A 355 T4 0,55kW ATEX 1400 2,57 1,49 0,55 3.400 53 19 2 279400106AXY CTH3-A 400 T4 0,75kW ATEX 1390 2,83 1,63 0,75 5.400 57 21 2 279450106AXY CTH3-A 450 T4 1,1kW ATEX 1400 4,33 2,49 1,1 7.600 60 38 2 279500106AXY CTH3-A 500 T4 1,5kW ATEX 1400 5,67 3,26 1,5 10.200 63 50 2 279560106AXY CTH3-A 560 T4 3kW ATEX 1430 10,7 6,17 3 13.200 66 55 2 Code Model R.P.M. Rated I (A) Rat. Power kW Air flow m3/h Sound dB (A) Weight Kg Connection diagram 230V 400V 279410106AXY CTH3-A 400 T6 0,37kW ATEX 900 2,2 1,27 0,37 3.550 47 21 2 279460106AXY CTH3-A 450 T6 0,37kW ATEX 910 3,39 1,95 0,37 4.850 51 38 2 279510106AXY CTH3-A 500 T6 0,75kW ATEX 910 3,39 1,95 0,75 6.450 54 50 2 279570106AXY CTH3-A 560 T6 0,75kW ATEX 910 3,39 1,95 0,75 8.400 56 55 2 279630106AXY CTH3-A 630 T6 1,5kW ATEX 940 6,45 3,71 1,5 12.200 60 70 2 279710106AXY CTH3-A 710 T6 2,2kW ATEX 940 10,3 5,94 2,2 19.000 65 101 2 279800106AXY CTH3-A 800 T6 4kW ATEX 960 16,5 9,46 4 25.000 67 118 2 THREE PHASE RANGE / serie trifásica 4 POLE / 4 POLOS Code Model R.P.M. Rated I (A) 230V Rated Power kW Air flow m3/h Sound dB (A) Weight Kg Connection diagram 279310103AXD CTH3-A 315 M4 0,25kW ATEX 1400 1,93 0,25 2.300 48 15 1 SINGLE PHASE RANGE / serie monofásica ATEX CLASSIFICATION / clasificación ATEX To place an order for an ATEX fan, you must replace the XY of the code with XE for zone 1, XN for zone 2, XC for zone 22 for conductive dust and XNC for zone 22 for non conductive dust. For non-sparking air passage and standardmotor, it must indicate XI / Para cursar un pedido de un ventilador ATEX se debe sustituir la XY del código por XE para zona 1, XN para zona 2, XC para zona 22 para polvo conductivo y XNC para zona 22 para polvo no conductivo. Para paso de aire antichispas y motor estándar debe indicar XI. ZONE / ZONA 1 ZONE / ZONA 2 ZONE / ZONA 22 POLVO CONDUCTIVO / CONDUCTIVE DUST POLVO NO CONDUCTIVO / NON CONDUCTIVE DUST FAN/VENTILADOR (Ex h IIB+H2 T4 Gb) + MOTOR (Ex eb IIC T4 Gb) FAN/VENTILADOR (Ex h IIB T3 Gc) + MOTOR (Ex ec IIC T3 Gc) FAN/VENTILADOR (Ex h IIIB T135ºC Db) + MOTOR (Ex tb IIIC T135ºC Db) FAN/VENTILADOR (Ex h IIIB T120ºC Dc) + MOTOR (Ex tc IIIB T120ºC Dc)
RkJQdWJsaXNoZXIy MTE4OTIxMQ==